AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Clinical Study | Publishing Language: Chinese | Open Access

Research on the accuracy of dynamic real-time navigation and digital guide navigation implanting techniques

Yaqin ZHAO1,2Aipeng LIU1Feng CEN3Kaiwen YANG1Yanfang LI1Wenzheng DENG1( )
Department of Stomatology, Wuzhou Red Cross Hospital, Wuzhou 543002, China
School of Stomatology, Youjiang Medical University for Nationalities, Baise 533000, China
Department of Medical Imaging, Wuzhou Red Cross Hospital, Wuzhou 543002, China
Show Author Information

Abstract

Objective

To compare the accuracies of implants with dynamic real - time navigation versus digital guide navigation to provide a reference for clinical precision dental implants.

Methods

Forty-six cases (seventy teeth) with missing teeth admitted to the Department of Stomatology, Wuzhou Red Cross Hospital from April 2018 to December 2019 were randomly divided into two groups (thirty-five teeth in each group) for dynamic real-time navigation and digital guide navigation implantation techniques. To compare the entry point, apex point, depth and angle deviation of the preoperative and postoperative position of implants in the two groups. SPSS 21.0 software was used for statistical analysis.

Results

Dental implants were successfully placed in both groups. The deviations of apex point, depth and angle in the dynamic real-time navigation group were all smaller than those in the digital guide navigation group, and the differences were statistically significant (P < 0.05). There was no statistically significant deviation in the entry point between the two groups (P > 0.05).

Conclusion

In this study, both techniques had good clinical effects. The accuracy of dynamic real-time navigation was higher than that of digital guidance.

CLC number: R78 Document code: A Article ID: 2096-1456(2021)03-0178-06

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 178-183

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHAO Y, LIU A, CEN F, et al. Research on the accuracy of dynamic real-time navigation and digital guide navigation implanting techniques. Journal of Prevention and Treatment for Stomatological Diseases, 2021, 29(3): 178-183. https://doi.org/10.12016/j.issn.2096-1456.2021.03.006

4

Views

0

Downloads

0

Crossref

0

Scopus

Received: 19 June 2020
Revised: 26 August 2020
Published: 20 March 2021
© 2021 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases