Basic Study | Publishing Language: Chinese | Open Access

The strength and the self-cleaning function of composite resin high strength fiber space maintainer

Zhongping YIN1, Ying ZHANG2, Miao HE1, Xiaolei TANG1, Yanhua XU3( )
Department of Stomatology, Daqing LongNan Hospital (The Fifth Subsidiary Hospital of Qiqihar Medical College), Daqing 163453, China
Department of stomatology of Ophthalmology and Otorhinolaryngology Hospital of daqing oilfield hospital, Daqing 163453, China
Department of Orthodontics, The Affiliated Stomatology Hospital of Kunming Medical University, Kunming 650031, China
Show Author Information

Abstract

Objective

To evaluate the mechanical properties and bacterial adhesion of the glass fiber-reinforced composite resin space maintainer.

Methods

The mechanical properties of the composite resin high-strength fiber (experimental group) and the band and loop type (control group) space maintainer were tested by universal material testing machine. The two types of space maintainer were placed on a plate with a strain of Streptococcus mutans. Scanning electron microscopy and viable cell counts were used to observe bacterial attachment.

Results

There was no significant difference in the maximum shear resistance between the experimental group (32.02 ± 4.315) N and the control group (33.35 ± 5.154) N space maintainer (P>0.05). Scanning electron microscope showed that streptococcal bacteria were attached to the surface of the two groups. The colony count quantity of the experimental group (10.02 ± 2.315)×104 CFU/mL was decreased compared with that of the control group (14.35 ± 2.154)×104 CFU/mL. The difference was statistically significant (P < 0.05).

Conclusion

The composite resin high-strength fiber and the band and loop type space maintainer have comparable mechanical strength; however, the composite resin high-strength fiber bacteria adheres less than the band and loop type, and the self-cleaning function is relatively good.

CLC number: R783 Document code: A Article ID: 2096-1456(2019)10-0634-04

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 634-637

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
YIN Z, ZHANG Y, HE M, et al. The strength and the self-cleaning function of composite resin high strength fiber space maintainer. Journal of Prevention and Treatment for Stomatological Diseases, 2019, 27(10): 634-637. https://doi.org/10.12016/j.issn.2096-1456.2019.10.004