AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (4.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Basic Study | Publishing Language: Chinese | Open Access

Effect of three kinds of medium molecular weight proteins on the corrosion resistance of Ni-Ti and stainless steel arch wires

Ye CUIZiru HUANGChunlin WANGConghua LIUChao ZHANG( )
Department of Orthodontics, Stomatological Hospital, Southern Medical University, Guangzhou 510280, China
Show Author Information

Abstract

Objective

To explore the influence and mechanism of different types of proteins on the corrosion resistance of alloy to provide a reference for the safe application and surface modification of nickel-titanium (Ni-Ti) and stainless steel bow wires in the clinic.

Methods

The effects of fibrinogen, IgG and mucin on the electrochemical corrosion resistance of Ni-Ti and stainless steel arch wires were tested by the potentiodynamic polarization method, and the repair ability of passive films on surfaces treated with the three proteins were tested by the cyclic polarization method. Inductively coupled plasma optical emission spectrometry (ICP-OES) was used to determine the types of corrosion products, and the surface morphology after corrosion was analyzed by scanning electron microscopy (SEM) and atomic force microscopy (AFM).

Results

The addition of fibrinogen, IgG or mucin to an alloy has different effects on its corrosion resistance. Adding protein can reduce the corrosion resistance of stainless steel alloys and slow the corrosion process of Ni-Ti alloys. The addition of mucin can improve the corrosion resistance of Ni-Ti alloy and the repair ability of passive film. Compared with mucin and IgG, fibrinogen can reduce the pitting resistance of Ni-Ti and stainless steel alloys.

Conclusion

Different types of proteins interact differently with the arch wire, form different deposition morphologies on the surface, and participate differently in the corrosion process of the alloy.

CLC number: R783.5 Document code: A Article ID: 2096-1456(2019)02-0083-07

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 83-89

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
CUI Y, HUANG Z, WANG C, et al. Effect of three kinds of medium molecular weight proteins on the corrosion resistance of Ni-Ti and stainless steel arch wires. Journal of Prevention and Treatment for Stomatological Diseases, 2019, 27(2): 83-89. https://doi.org/10.12016/j.issn.2096-1456.2019.02.003

73

Views

0

Downloads

0

Crossref

0

Scopus

Received: 15 October 2018
Revised: 03 November 2018
Published: 20 February 2019
© 2019 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases