Clinical application of a digital whole-process surgical guide plate for immediate implant placement in the molar area

Shaobing LIJia NI( )Xueyang ZHANG( )Yanhong HUANGMingdeng RONGHaibin LU
Department of Periodontal Implantology, Stomatological Hospital, Southern Medical University, Guangzhou 510280, China
Show Author Information

Abstract

Objective

To evaluate the clinical effect of a digital whole-process surgical guide for immediate implantation in the molar area.

Methods

Twenty-six patients with molar extraction plans were accepted for preoperative CBCT and model construction. Computer software was used to design the ideal three-dimensional position of the implant. The control group of 13 patients underwent immediate implantation with a free hand operation, whereas the experimental group of 13 patients underwent preparation and implant insertion under the guidance of a surgical guide. Bone grafting was performed, and a good initial stability was achieved. After 5 to 6 months, osseointegration was achieved, and the final restoration was delivered. After surgery, the accuracy of the three-dimensional position of the implants was measured, and at the 6 month return visit, the modified Plaque Index (mPLI), modified Sulcular Bleeding Index (mSBI) and probing depth (PD) were measured.

Results

In the control group and experimental group, the vertical errors at the top of the implants were 1.246 ± 0.072 mm and 0.628 ± 0.046 mm (t = 26.078, P < 0.001), respectively, and the horizontal errors were 1.563 ± 0.086 mm and 0.546 ± 0.056 mm (t = 35.813, P < 0.001), respectively; and the vertical errors at the root of the implants were 1.352 ± 0.042 mm and 0.532 ± 0.030 mm (t = 57.021, P < 0.001), respectively, and the horizontal errors were 1.645 ± 0.076 mm and 0.625 ± 0.072 mm (t = 35.086, P < 0.001), respectively. For the experimental group, the mPLI value was 0.923 ± 0.760, the mSBI value was 0.846 ± 0.689, and the PD value was 3.460 ± 0.713 mm, which were significantly lower than those of the control group. For the control group, the mPLI value was 1.769 ± 0.927 (t = 2.546, P = 0.018), the mSBI value was 1.692 ± 0.947 (t = 22.605, P = 0.016) and the PD value was (4.579 ± 0.475) mm (t = 4.709, P < 0.001).

Conclusion

A digital surgical guide plate can increase the precision of immediate implantation and the peri-implant health in the molar area.

CLC number: R783.6 Document code: A Article ID: 2096-1456(2018)08-0508-06

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 508-513

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LI S, NI J, ZHANG X, et al. Clinical application of a digital whole-process surgical guide plate for immediate implant placement in the molar area. Journal of Prevention and Treatment for Stomatological Diseases, 2018, 26(8): 508-513. https://doi.org/10.12016/j.issn.2096-1456.2018.08.006

92

Views

0

Downloads

0

Crossref

0

Scopus

Received: 06 May 2018
Revised: 15 June 2018
Published: 20 August 2018
© 2018 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases