AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Basic Study | Publishing Language: Chinese | Open Access

Effects of different root canal filling stop on quality of root canal filling in root canals obturated with GuttaFlow

Jingjing LIJunliang LIYafan GAOYajie QIANQin HEWeidong YANG( )
Department of Endodontics, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing 210008, China
Show Author Information

Abstract

Objective

To investigate the effects of different root canal filling stop on quality of root canal filling and apical sealing in root canals obturated with GuttaFlow.

Methods

60 teeth were randomly divided into three groups, using different root canal filling stops to shape the root canals with MTwo (25/06) file. All root canals were obturated with Gutta Flow, and the overfilling of the root canals were recorded and evaluated by X-ray. And the apical microleakage of teeth was evaluated by transparent teeth technique.

Results

The roots were prepared with MTwo (25/06) as master apical file, the overfilling rate of the root canals in root canal filling stop was higher as the distance from the apex was shorter, but there was no significant difference. The under-filling rate of the root canals in root canal filling stop was higher as the distance from the apex was longer. And the under-filled root canals in root canal filling stop 0.5 mm from the apex showed a statistically significant difference with 2 mm. The mean dyeing penetration length in 0.5 mm and 1 mm group was significantly shorter than 2 mm group.

Conclusion

A suitable root canal filling stop could improve the quality of root canal filling in root canals obturated with GuttaFlow.

CLC number: R781.3 Document code: A Article ID: 2096-1456(2018)01-0026-05

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 26-30

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LI J, LI J, GAO Y, et al. Effects of different root canal filling stop on quality of root canal filling in root canals obturated with GuttaFlow. Journal of Prevention and Treatment for Stomatological Diseases, 2018, 26(1): 26-30. https://doi.org/10.12016/j.issn.2096-1456.2018.01.005

6

Views

0

Downloads

0

Crossref

0

Scopus

Received: 21 July 2017
Revised: 04 October 2017
Published: 20 January 2018
© 2018 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases