AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Special Article | Publishing Language: Chinese | Open Access

In vitro study of wear of Ceramage and IPS e.max Press

Shandan HELiqiang XUGuojun SONGYuyan ZHENG( )
Center of Stomatology, 2nd Clinical Medical College of Jinan University, Shenzhen People's Hospital
Show Author Information

Abstract

Objective

To compare the wear of Ceramage and IPS e.max Press offering foundation for nonmetallic materials selection in clinical.

Methods

20 class Ⅰ cavities were prepared in the approximal flattened sides of the extracted human maxillary first molars. The cavities were divided into 2 groups randomly, and then restored with Ceramage or IPS e.max Press. Inlays were prepared according to the manufactures' instructions with indirect methods and cemented with Varolink N. The non-wear extracted maxillary third molars were used as antagonistic enamel cusps after standardized prepared. After the self-made wear-testing device concluded 200,000 cycles under a load of 20 N, the wear depth of specimens and antagonistic enamel cusps was assessed by Kavo PREP assistant.

Results

The wear in Ceramage group was (298.30 ± 40.02) μm, while the wear of normal enamel was (206.60 ± 49.17) μm. The wear in IPS e.max Press group was (212.90 ± 61.21) μm, while the wear of normal enamel was (217.00 ± 25.10) μm. The wear of IPS e.max Press inlays was higher than Ceramage inlays (P < 0.05). Ceramage inlays showed higher wear than normal enamel (P < 0.05), while IPS e.max Press inlays was not statistically different from the normal enamel (P > 0.05).

Conclusions

Ceramage has more wear than IPS e.max Press. Ceramage shows higher wear compared with normal enamel, while IPS e.max Press has lower antagonistic war compared with normal enamel.

CLC number: R783.1 Document code: A Article ID: 2096-1456(2017)10-0626-07

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 626-632

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
HE S, XU L, SONG G, et al. In vitro study of wear of Ceramage and IPS e.max Press. Journal of Prevention and Treatment for Stomatological Diseases, 2017, 25(10): 626-632. https://doi.org/10.12016/j.issn.2096-1456.2017.10.003

95

Views

0

Downloads

0

Crossref

0

Scopus

Received: 11 July 2017
Revised: 04 August 2017
Published: 20 October 2017
© 2017 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases