AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Accuracy evaluation of digital surgical template in angled implantation in the maxillary posterior region

Lei GUOJing YANGYuanqin WANG( )
Department of Dental Implant, Huizhou Stomatological Hospital & The Affiliated Huizhou Stomatological Hospital of Jinan University, Huizhou 516000, China
Show Author Information

Abstract

Objective

To evaluate the accuracy of digital surgical guide in tilted implant in the maxillary posterior region.

Methods

Jaw data from 14 patients were scanned using cone beam computed tomography (CBCT), and digital models were acquired by scanning maxillary plaster models. Implant software was employed to process jaw data and digital models in order to design the surgical template. Then the stereolithographic (SLA) surgical template was created to guide the surgery. After that CBCT data was collected again and compared with the data collected before. Deviations between the actual implant position and the planned implant position were analyzed.

Results

Central deviation at the hex and apex between the actual implant and the planned implant was almost constant with a mean of (0.625 ± 0.183) mm and (0.820 ± 0.208) mm. Mean value of horizontal deviation at the hex was (0.314 ± 0.070) mm, horizontal deviation at the apex was (0.509 ± 0.139) mm, vertical deviation at the hex was (0.538 ± 0.178) mm, vertical deviation at the apex was (0.638 ± 0.178) mm.

Conclusion

Angled implantation in the maxillary posterior region can reduce risks and trauma as well as the difficulties and duration of surgery. However, our data suggested that significant deviations existed in the actual implant position and the planned implant position.

CLC number: R783.4 Document code: A Article ID: 2096-1456(2017)07-0435-04

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 435-438

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
GUO L, YANG J, WANG Y. Accuracy evaluation of digital surgical template in angled implantation in the maxillary posterior region. Journal of Prevention and Treatment for Stomatological Diseases, 2017, 25(7): 435-438. https://doi.org/10.12016/j.issn.2096-1456.2017.07.006

77

Views

0

Downloads

0

Crossref

0

Scopus

Received: 10 March 2017
Revised: 18 April 2017
Published: 20 July 2017
© 2017 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases