Basic Study | Publishing Language: Chinese | Open Access

In vitro evaluation of retreatment efficacy of Mtwo rotary instruments

Fangli TONG1( )Qin YANG2Xiongqun CENG1
Department of Endodontics, Stomatological Hospital, Southern Medical University, Guangzhou 510280, China
Haizhu Branch, Stomatological Hospital, Southern Medical University, Guangzhou 510280, China
Show Author Information

Abstract

Objective

To evaluate the efficacy of Mtwo rotary instruments during root canal retreatment.

Methods

Thirty mandibular premolars with oval root canal were prepared with ProTaper rotary instruments and obturated with lateral condensation method. The samples were divided into 2 groups. In Mtwo group, the filling materials were removed with Mtwo retreatment system and Mtwo basic instruments. Inmanual stainless group, the filling material were removed with manual instruments. The percentage of residual filling material was measured with image proplus softwareand the operating time was recorded.

Results

The percentage of residual filling material in Mtwo group was significantly lower than manual group in middle third, but the opposite result can be found in the coronal third. In the whole canal, no significant difference was found between the two groups. The mean operating time in Mtwo group was significantly shorter than manual group.

Conclusion

Mtwo rotary instruments can shorten the time of retreatment, neither of the groups can remove the filling material in oval root canal completely.

CLC number: R781.05 Document code: A Article ID: 2096-1456(2017)07-0426-04

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 426-429

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
TONG F, YANG Q, CENG X. In vitro evaluation of retreatment efficacy of Mtwo rotary instruments. Journal of Prevention and Treatment for Stomatological Diseases, 2017, 25(7): 426-429. https://doi.org/10.12016/j.issn.2096-1456.2017.07.004

89

Views

0

Downloads

0

Crossref

0

Scopus

Received: 26 January 2017
Revised: 24 March 2017
Published: 20 July 2017
© 2017 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases