Special Article | Publishing Language: Chinese | Open Access

Influence of different heat treatments on the corrosion behavior of a new type of high palladium dental alloy

Department of Stomatology, Shenzhen People's Hospital, Shenzhen 518020, China
Department of Prosthodontics, West China School of Stomatology, Sichuan University, Chengdu 610041, China
Show Author Information

Abstract

Objective

To evaluate the influence of different heat treatments on the corrosion behavior of a new Pd-Ag-In-Ga alloy.

Methods

The corrosion of a new Pd-Ag-In-Ga alloy was tested according to ISO 10271:2001/cor.1: 2005(E). Taken as comparison, a commercial high-palladium alloy (Spartan® Plus) was also employed in the study. For electrochemical corrosion test, the open-circuit potential (Eocp) and potentiodynamic polarization curve were recorded and then the electrochemical parameters, namely corrosion potential (Ecorr) and corrosion current density (Icorr) calculated. The surfaces of the specimens that before and after corrosion test were observed by scanning electron microscopy (SEM).

Results

Both of the high-palladium alloys had lower corrosion tendency and higher corrosion resistance by heat treatment in the ISO 10271 electrochemical corrosion test. For both alloys, heat treatment at 500 ℃ was found to be effective in improving the corrosion resistance as the best datas of electrochemical parameters (Eocp, Ecorr, Icorr) were detected among the four temperature groups. However, no evidence showed that there was significant difference in corrosion resistance between the two alloys. Comparison of surface morphology of the specimens before and after electrochemical experiments by SEM demonstrated that all groups of the two alloys were visible of pitting corrosion and crevice corrosion phenomenon that gradually became less with increasing heat treatment temperature. Horizontal comparing among the groups of the two alloys, no apparent differences in the distribution of pitting and crevice corrosion was found.

Conclusion

The variation in compositions of high-palladium alloys did not cause significant difference in corrosion behavior due to the identical palladium matrix. The similarity in corrosion behavior among the two high-palladium alloys might be attributed to the predominant palladium content.

CLC number: R783.1 Document code: A Article ID: 2096-1456(2017)02-080-07

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 80-86

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LIU J-j, MENG Y-k. Influence of different heat treatments on the corrosion behavior of a new type of high palladium dental alloy. Journal of Prevention and Treatment for Stomatological Diseases, 2017, 25(2): 80-86. https://doi.org/10.12016/j.issn.2096-1456.2017.02.003

277

Views

1

Downloads

0

Crossref

0

Scopus

Received: 21 September 2016
Revised: 03 December 2016
Published: 20 February 2017
© 2017 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases