AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.8 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Evaluation of the absorption of alveolar bone in different impression methods for repairment of Kennedy Class Ⅱ denture defect

Li-bo WANG1, Yue-zhi LI2, Ji-ying WEI1( ), Xue-jing ZHANG1, Lan LAN3
Department of Prosthodontics, Stomatological Hospital Affiliated to Zunyi Medical College, Zunyi 563003, China
Chongqing Traditional Chinese Medicine Hospital, Chongqing 400013, China
Zunyi Medical College, Zunyi 563003, China
Show Author Information

Abstract

Objective

To evaluate the absorption of alveolar bone in anatomic impression and functional impression technique in the repairment of Kennedy class Ⅱ denture defect by cone beam CT(CBCT).

Methods

16 patients with mandibular Kennedy Class Ⅱ denture defect were randomly divided into the function group and the anatomical group (n = 8). The function group adopted the functional impression, the anatomical group used anatomic denture impression for denture making. Before denture wearing and after 6 months of normal use of denture, CBCT were used to measure the height of residual alveolar bone in the mesial and distal alveolar bone, and the height difference between the anterior and posterior teeth.

Results

After 6 months of denture wearing, the height difference of the mesial (n = 0.742, P < 0.05) and distal (t = 5.727, P < 0.05) of the terminal abutment alveolar bone in anatomical group is significantly higher than that of the function group (P < 0.05); the height of residual alveolar bone of anatomical group and functional group has no significant difference (P > 0.05).

Conclusion

The denture made by function impression can reduce the absorption of alveolar bone in the mesial and distal of terminal abutment teeth, while different impression methods don’t have obvious influence on the absorption of residual alveolar bone during the short observation research term.

CLC number: R783.4 Document code: A Article ID: 2096-1456(2016)12-724-05

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 724-728

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
WANG L-b, LI Y-z, WEI J-y, et al. Evaluation of the absorption of alveolar bone in different impression methods for repairment of Kennedy Class Ⅱ denture defect. Journal of Prevention and Treatment for Stomatological Diseases, 2016, 24(12): 724-728. https://doi.org/10.12016/j.issn.2096-1456.2016.12.009

356

Views

1

Downloads

0

Crossref

0

Scopus

Received: 23 February 2016
Revised: 04 May 2016
Published: 20 December 2016
© 2016 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases