AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Special Article | Publishing Language: Chinese | Open Access

Initial stability analysis of the torque-resisted orthodontic miniscrew anchorage

Jian-na ZHANGShao-hai CHANG( )Yu-shan YEYing-juan LU
Institute of Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou 510120, China
Show Author Information

Abstract

Objective

To compare the initial stability difference between a new designed torque-resisted orthodontic miniscrew anchorage and commercial miniscrew anchorage by torque tests and resonance frequency analysis (RFA).

Methods

After predrilled 4 mm-deep holes with a diameter of 1. 0 mm, two different miniscrews were implanted into the swine ribs for measurement of maximum insertion torque (MIT), maximum removal torque (MRT) and RFA which was recorded as implant stability quotient (ISQ). Statistical analysis was done for all data by SPSS 13. 0.

Results

The mean value of MIT, MRT, ISQ for new miniscrews were (11. 86 ± 1. 58) N·cm, (8. 45 ± 2. 24) N· cm and 61. 80 ± 2. 9 while for commercial miniscrews were (10. 36 ± 1. 42) N·cm, (6. 76 ± 1. 78) N·cm and 58. 15 ± 2. 98. The differences between the two miniscrews were statistically significant (P < 0. 05).

Conclusion

The torque-resisted miniscrews were more stable than commercial miniscrews.

CLC number: R783.1 Document code: A Article ID: 2096-1456(2016)03-137-05

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 137-141

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHANG J-n, CHANG S-h, YE Y-s, et al. Initial stability analysis of the torque-resisted orthodontic miniscrew anchorage. Journal of Prevention and Treatment for Stomatological Diseases, 2016, 24(3): 137-141. https://doi.org/10.12016/j.issn.2096-1456.2016.03.002

304

Views

0

Downloads

0

Crossref

0

Scopus

Received: 02 September 2015
Revised: 11 October 2025
Published: 20 March 2016
© 2016 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases