AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Development and application of an all-solid-state Mg2+ microneedle sensor for crop in-situ detection

Zhihao WANG1,2Chengxiao FAN1,2Zhuo WANG1,3Lan HUANG1,3Zhongyi WANG1,2( )
College of Information and Electrical Engineering, China Agricultural University, Beijing 100083, China
Key Laboratory of Modern Precision Agriculture System Integration Research, Ministry of Education, Beijing 100083, China
Key Laboratory of Agricultural Information Acquisition Technology, Ministry of Agriculture and Rural Affairs, Beijing 100083, China
Show Author Information

Abstract

A microneedle all-solid-state selective electrode (ASS-ISE) was developed to rapidly in-situ detect Mg2+ in the crop stems. The electrode consists 3 parts from the inner to the outer layer, consisting of stainless-steel microneedle, solid contact and ion ion-selective membrane (ISM). This sensor was prepared as follows. Firstly, a stainless-steel microneedle was used as the conductive substrates. The graphene conductive layer was coated on the tip of the microneedle after drying for 12 h. And then, a solid-state contact of Poly (3,4-ethylenedioxythiophene) / Poly (styrene sulfonate, PEDOT/PSS) was electroplated onto the graphene surface; After the second drying for 12 h, an ion selective membrane (ISM) was coated on the tip of the microneedle; The sensor was fabricated after the third drying time of 12 h and activation. A series of the accurate measurements were carried out on the sensor. Initially, the sensor was calibrated using a standard concentration of MgCl2 solution. The performance of the graphene-PEDOT solid-state contact was tested using scanning electron microscopy (SEM), water layer test, and electrochemical impedance spectroscopy (EIS). A comparison test was then made on two types of sensors, the needle-graphene-PEDOT-ISM and the needle-ISM sensors. Finally, the sensor was applied to detect the Mg2+ in wheat seedling stalks. Both pure agar and deionized water were used to verify the reliability of the detection. The potentiometric calibration demonstrated that the sensor exhibited a rapid response with a response time of 7.0 s, and a detection limit as low as 1.0 × 10-7 mol/L. The better detection was achieved with a Nernst slope of 27.04 mV/dec and a lifetime of at least 30 days. The SEM test demonstrated that the graphene-PEDOT solid-state contact was substantially improved in the low-frequency capacitance between the ion-selective membrane and the stainless-steel substrate. The water layer test demonstrated that the graphene-PEDOT solid-state contact was effectively inhibited the formation of the water layer for the high stability of the ion-electron transfer of the sensor, thus reducing the signal drift. The EIS fitting test showed that there were the similar equivalent circuit diagrams of the two types of sensors. In addition, the graphene-PEDOT solid-state contact structure was effectively reduced the charge transfer resistance on the sensor surface. The stability of the response potential was improved during the process. The sensor was performed best to detect the concentration of Mg2+ in the stems of the wheat seedlings in the range of about 1.0 ×10-3.42-10-3.03 mol/L. In summary, a wide range of the promising prospects was also gained in the low detection limit, the stable potential response, in-situ detection of Mg2+ concentration in the crop stalks.

CLC number: O657.15 Document code: A

References

【1】
【1】
 
 
Transactions of the Chinese Society of Agricultural Engineering
Pages 29-36

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
WANG Z, FAN C, WANG Z, et al. Development and application of an all-solid-state Mg2+ microneedle sensor for crop in-situ detection. Transactions of the Chinese Society of Agricultural Engineering, 2025, 41(9): 29-36. https://doi.org/10.11975/j.issn.1002-6819.202410108

557

Views

2

Downloads

0

Crossref

0

Web of Science

2

Scopus

Received: 16 October 2024
Revised: 08 April 2025
Published: 15 May 2025
© Chinese Society of Agricultural Engineering 2025