AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.9 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Simulation and experimental study of the air distribution characteristics of large-span film air duct in greenhouses

College of Energy Engineering, Zhejiang University, Hangzhou 310027, China
Show Author Information

Abstract

Air handling units (AHUs) with long distance flexible film air ducts are commonly adopted in modern large-scale greenhouses for temperature controlling. To study the performance of this type of AHU, theoretical analysis and numerical simulation methods were used to discover its air supply characteristics, and a full-scale experiment was carried out to verify the correctness of the calculation model. The calculation showed that the static pressure of different cross-sections in the thin film air duct sharply decreased to 0 at the small-hole opening, where the airflow velocity increased significantly. However, this influence only exists locally and had little effect on the pressure and gas velocity fields inside the wind duct. The velocity and velocity distribution of the gas flowing out from different openings on the same section of the wind duct are basically the same. Taking the wind speed of 2.45 m/s at the inlet end of the wind duct as an example, the maximum velocity of the airflow at the opening position of the wind duct wall at 60.06 m is 5.64 m/s, located at the center of the opening and flowing outward perpendicular to the opening plane. The velocity distribution is that the center has the highest velocity, and the closer to the edge of the hole, the lower the velocity. The volum of the airflow flowing out through the openings on the wall of the wind duct along the length direction shows that the air supply remains basically constant under different inlet wind speed conditions, and the uniformity coefficient is greater than 0.92. This indicates that this type of AHU can evenly distribute airflow along the length direction, and can evenly distribute heat or cold in the large space of the greenhouse, thus providing a guarantee for maintaining a uniform temperature field in modern large greenhouses.

CLC number: S625.5+1 Document code: A

References

【1】
【1】
 
 
Transactions of the Chinese Society of Agricultural Engineering
Pages 204-211

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LU X, YU C. Simulation and experimental study of the air distribution characteristics of large-span film air duct in greenhouses. Transactions of the Chinese Society of Agricultural Engineering, 2024, 40(15): 204-211. https://doi.org/10.11975/j.issn.1002-6819.202401105

713

Views

10

Downloads

0

Crossref

0

Web of Science

1

Scopus

Received: 14 January 2024
Revised: 24 June 2024
Published: 15 August 2024
© Chinese Society of Agricultural Engineering 2024