AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (9.5 MB)
Collect
AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline

Seismic performance of partially encased composite (PEC) steel-concrete columns with T-shaped sections

Bida ZHAO( ), Tianchi SHEN, Xiong ZHU, Yunjie GUAN
College of Civil Engineering, Zhejiang University of Technology, Hangzhou 310023, P. R. China
Show Author Information

Abstract

The present study investigates the seismic performance of partially encased composite steel-concrete columns with T-shaped sections (abbreviated as T-PEC columns). Five T-PEC column specimens with different axial compression ratios and main steel component (MSC) configurations are tested under cyclic horizontal load. Furthermore, MSCs are available in various forms, including solid-web steel and honeycomb steel with openings in the steel web. Based on the test and finite element (FE) analysis results, the impact of steel web openings and the axial compression ratio on the seismic performance of T-PEC columns is investigated. The findings indicate that all T-PEC column specimens failed in proximity to the column base, exhibiting plastic softening of the steel flange and adjacent concrete crushing. This is indicative of a typical cross-section compression-bending failure mode. The load-displacement hysteresis curves of all specimens were full, with the hysteresis loops at the same loading level almost coinciding, indicating effective energy dissipation and load-bearing stability. Steel web openings degraded deformability, ductility, and energy dissipation capacity of T-PEC columns. As the axial compression ratio increased, the lateral stiffness and lateral resistance capacity of the T-PEC columns increased, but the deformability, ductility, and energy dissipation capacity decreased. Both the full-section plasticity method and numerical integration method provided reasonably accurate estimates of the flexural capacity of the T-PEC column sections under the action of compression-bending load.

CLC number: TU398 Document code: A Article ID: 2096-6717(2026)05-0001-12

References

【1】
【1】
 
 
Journal of Civil and Environmental Engineering
Pages 1-12

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHAO B, SHEN T, ZHU X, et al. Seismic performance of partially encased composite (PEC) steel-concrete columns with T-shaped sections. Journal of Civil and Environmental Engineering, 2026, 48(5): 1-12. https://doi.org/10.11835/j.issn.2096-6717.2025.068

1

Views

0

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 07 March 2025
Published: 01 October 2026
© Journal of Civil and Environmental Engineering