AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (11.5 MB)
Collect
AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Process parameter optimization for microfocus X-Ray digital radio-graphy inspection of small-diameter aero-engine tube welds

Tao ZHANG1a,1bLong MA2Wei YUAN1a,1bXin ZHOU1a,1bFenglin LIU1a,1b( )
Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, P. R. China
Engineering Research Center of Industrial Computed Tomography Nondestructive Testing, Ministry of Education, Chongqing University, Chongqing 400044, P. R. China
AECC Aviation Power Co. Ltd., Xi’an 710000, P. R. China
Show Author Information

Abstract

Microfocus X-ray digital radiography (DR) offers high image resolution and is therefore well suited for the nondestructive inspection of small-diameter aero-engine tube welds. To optimize the inspection process parameters for microfocus DR applied to small-diameter aero-engine tube welds, a numerical model describing the relationship between process parameters and DR image quality was developed to guide parameter selection. First, a step wedge made of the same material as the aero-engine small-diameter tubes was used to simulate different X-ray penetration thicknesses of the workpiece. A quadratic regression model was then established to characterize the relationships between key process parameters (tube voltage, tube current, magnification, and penetration thickness, etc.) and DR image quality indexes (spatial resolution and contrast-to-noise ratio). Then, three small-diameter aero-engine tubes with different wall thicknesses were selected as representative workpieces, and the optimal sequence of process parameters was determined using a non-dominated genetic algorithm. Experimental results show that the measured DR image quality indices closely match the predicted values of the model, demonstrating that the proposed quadratic regression model can effectively predict the relationship between process parameters and DR image quality. Compared with conventional methods that adjust process parameters individually, the proposed method exhibits higher efficiency and stronger guidance and can be extended to similar DR inspection applications.

CLC number: TH89 Document code: A Article ID: 1000-582X(2026)03-071-13

References

【1】
【1】
 
 
Journal of Chongqing University
Pages 71-83

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHANG T, MA L, YUAN W, et al. Process parameter optimization for microfocus X-Ray digital radio-graphy inspection of small-diameter aero-engine tube welds. Journal of Chongqing University, 2026, 49(3): 71-83. https://doi.org/10.11835/j.issn.1000-582X.2026.03.007

111

Views

0

Downloads

0

Crossref

0

Scopus

Received: 15 June 2025
Published: 01 March 2026
© Journal of Chongqing University