AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (13.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Article | Publishing Language: Chinese

Comparison of total ozone column observed under high solar zenith angles at Zhongshan station

Guanghui ZHENG1,2, Tianzhen JU1, Minghu DING2,3, Lin'gen BIAN2, Xiangdong ZHENG2,3( )
College of Geography and Environment, Northwest Normal University, Lanzhou 730070, China
China Academy of Meteorological Sciences, Beijing 100081, China
Laboratory of Polar Sea Ice Climate System and Weather and Climate, Ministry of Education, Fudan University, Shanghai 200433, China
Show Author Information

Abstract

Daily minimum solar zenith angle (SZA)≥80° during or near the period of polar night (May—July) at Zhongshan station of China (69.37°S, 76.38°E) in Antarctic restricts ground-based observations of Total Ozone Column (TOC) by using direct solar light (DS), which limits further accurate understanding of TOC seasonality. To address this issue, the following four types of TOC observations at SZA≥80°: (1) Brewer ozone spectrophotometer DS, TOCDS≥80°, (2) focused sun-disk (FS), TOCFS≥80°, (3) focused moon disk (FM), TOCFM and (4) SAOZ spectrometer zenith twilight observations, TOCSAOZ, made from 2009 to 2023 are analyzed with reference to the Brewer DS observations within SZA of [72°,80°), i.e., TOCDS [72,80°).The results show that, on average, TOCDS≥80° are lower by (5.5±9.5(1σ)) DU or (2.1±4.1(1σ)) % when SZA is [81°,81.5°) while TOCFS≥80° are higher by (2.8±4.3(1σ)) DU or (1.75±4.3(1σ))% when SZA is [80°, 84.5°). The fixed stratospheric ozone layer height (~22 km) in the air mass factor (μ) calculation causes a decreased μ with increasing SZA, which is the main reason for the higher TOCFS≥80°. On average, TOCFM is lower by (6.8±16.7(1σ)) DU or (2.2±6.8(1σ))% while TOCSAOZ is lower by (12.1±12.9(1σ)) DU or (4.4%±5.0(1σ))% on average. The longer optical path of twilight in the atmosphere together with the nature latitudinal distribution of TOC are the reasons for lower TOCSAOZ values. The significant diurnal variation of TOC during the "ozone hole" (TOC≤220 DU) period increases the differences between those observed TOC at SZA≥80° and the reference. It is confirmed that the annual "ozone hole" at Zhongshan station starts in August. The average TOC is within 270—290 DU while the minimum value can be ~230 DU, indicating that ozone depletion has already occurred during the polar night when the polar vortex has been well developed. The secondary seasonal lower TOC in autumn (March), which are due to the influence of the nature stratospheric Brewer-Dobson circulation, is similar to the lowest TOC in autumn in the middle and high latitudes of the northern Hemisphere. FS observations should be preferentially applied when the SZA≥80°, and FM should be implemented because it is the only effective way during the polar night for routine TOC observations.

CLC number: P412

References

【1】
【1】
 
 
Acta Meteorologica Sinica
Pages 159-171

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHENG G, JU T, DING M, et al. Comparison of total ozone column observed under high solar zenith angles at Zhongshan station. Acta Meteorologica Sinica, 2026, 84(1): 159-171. https://doi.org/10.11676/qxxb2025.20240165

664

Views

4

Downloads

0

Crossref

0

CSCD

Received: 23 September 2024
Revised: 24 January 2025
Published: 25 February 2026
Copyright © 2026 Acta Meteorologica Sinica. All rights reserved.