AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (860 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Original Article | Publishing Language: Chinese | Open Access

Determination study of α-dicarbonyl degradation products in icodextrin peritoneal dialysis solution by o-phenylenediamine derivatization HPLC-MS/MS

School of Pharmacy, China Pharmaceutical University, Nanjing 211198, China
Show Author Information

Abstract

Icodextrin peritoneal dialysis solution may produce cytotoxic α-dicarbonyl degradation products during heat sterilization, which must be monitored and controlled. The study established an o-phenylenediamine (OPD) derivatization HPLC-MS/MS method for the detection of these degradation products, enabling qualitative and quantitative analysis of α-dicarbonyl degradation products in icodextrin peritoneal dialysis solution. The results indicated that the main α-dicarbonyl degradation products in icodextrin peritoneal dialysis solution are 3-deoxyglucosone (3-DG), 3-deoxygalactosone (3-DGal), 4-deoxyglucosone (4-DG), and 3,4-dideoxyglucosone-3-ene (3,4-DGE), along with two monocarbonyl degradation products, furfural and 5-hydroxymethylfurfural. The quantitative method for 3-DG, 3-DGal, 3,4-DGE and their structural analog, glucosone, was validated. 3-DG, 3-DGal, and glucosone exhibited good linear relationships within the range of 5-150 ng/mL, while 3,4-DGE showed good linearity in the range of 1-150 ng/mL. The spiked recovery rates for all compounds were between 86.8% and 100.0%. The detection limits for glucosone, 3-DG, and 3-DGal were approximately 2.4 ng/mL, and approximately 0.5 ng/mL for 3,4-DGE. The method established in this study can accurately determine α-dicarbonyl degradation products in icodextrin peritoneal dialysis solution, providing an important basis for the quality control.

CLC number: R917 Document code: A Article ID: 1000-5048(2026)-2-233-7

References

【1】
【1】
 
 
Journal of China Pharmaceutical University
Pages 233-239

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
FAN X, ZHANG L, ZHENG F. Determination study of α-dicarbonyl degradation products in icodextrin peritoneal dialysis solution by o-phenylenediamine derivatization HPLC-MS/MS. Journal of China Pharmaceutical University, 2026, 57(2): 233-239. https://doi.org/10.11665/j.issn.1000-5048.2025080602

322

Views

3

Downloads

0

Crossref

0

CSCD

Received: 06 August 2025
Published: 25 April 2026
© 2026 The Editorial Office of Journal of China Pharmaceutical University

This is an open access article under the CC BY-NC-ND license (https://creativecommons.org/licenses/by-nc-nd/4.0/).