AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (609 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Original Article | Publishing Language: Chinese | Open Access

Determination of docusate sodium by ion-pair high-performance liquid chromatography

Lirong CAI1,2( ), Haiping SHU3, Sha XIAO3, Yue TAN3, Jinfeng ZHENG1, Changliang LI1, Yanming LIU1( )
Hunan Institute for Drug Control, NMPA Key Laboratory for Pharmaceutical Excipients Engineering Technology Research, Changsha 410001
NMPA Key Laboratory for Research and Evaluation of Pharmaceutical Preparation and Excipients, Nanjing 211198
Hunan Warrant Pharmaceutical Co., Ltd, Changsha 410006, China
Show Author Information

Abstract

To reduce the dependency on high-carbon-load chromatographic columns,a new method has been established for the determination of the content of docusate sodium using ion-pair high-performance liquid chromatography (IP-HPLC). Tetrapropylammonium chloride was used as the ion-pair reagent with a mobile phase, composition of acetonitrile:10 mmol/L tetrapropylammonium chloride solution = 66∶34, adjusting pH to 6.5 with 0.1% phosphoric acid solution,flow rate of 1.5 mL/min, detection wavelength of 214 nm,column temperature of 35 °C, and an injection volume of 25 μL,and quantified by an external standard method. The main peak of docusate sodium exhibited a tailing factor of 1.34. The method showed good linearity within the range of 0.02 mg/mL to 0.40 mg/mL, with a correlation coefficient (r) of 0.999 9. It also demonstrated good repeatability, with recovery ranging from 97.0% to 98.2% (n=6). The quantification limit was 3.31 μg/mL, and the detection limit was 2.76 μg/mL.In summary,the new method shows good durability, a wide linear range, and high sensitivity, it is suitable for the determination of docusate sodium.

CLC number: R917 Document code: A Article ID: 1000-5048(2025)-2-183-5

References

【1】
【1】
 
 
Journal of China Pharmaceutical University
Pages 183-187

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
CAI L, SHU H, XIAO S, et al. Determination of docusate sodium by ion-pair high-performance liquid chromatography. Journal of China Pharmaceutical University, 2025, 56(2): 183-187. https://doi.org/10.11665/j.issn.1000-5048.2024081002

1

Views

0

Downloads

0

Crossref

0

CSCD

Received: 10 August 2024
Published: 25 April 2025
© 2025 The Editorial Office of Journal of China Pharmaceutical University

This is an open access article under the CC BY-NC-ND license (https://creativecommons.org/licenses/by-nc-nd/4.0/).