AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (714.9 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Determination of 26 trace cathinones new psychoactive substances in sewage by HPLC-MS/MS

Bin DENG1, Na ZHU1, Zhendong HUA2,3, Youmei WANG2,3, Mengxiang SU1,3( )
Department of Pharmaceutical Analysis, School of Pharmacy, China Pharmaceutical University, Nanjing 210009
Key Laboratory of Drug Monitoring and Control & Drug Intelligence and Forensic Center, Ministry of Public Security , Beijing 100741
China National Narcotics Control Commission-China Pharmaceutical UniversityJoint Laboratory on Key Technologies of Narcotics Control , Nanjing 210009, China
Show Author Information

Abstract

A method for the pretreatment and qualitative detection of 26 trace cathinone new psychoactive substances in wastewater was established and applied in actual wastewater cases. The effluent samples were eluted on the Oasis PRiME HLB solid phase extraction column by ultra-pure water drenching and methanol solution, then dried with nitrogen at 40 ℃, and finally re-dissolved with 0.1% formic acid-acetonitrile solution (95∶5), and detected by liquid chromatography-tandem mass spectrometry, The effluent sample was determined by high-performance liquid chromatography-Tandem mass spectrometry (HPLC-MS/MS) using selected reaction monitoring (SRM) mode and separated on chromatographic column UPLC BEH C18(100 mm×2.1 mm, 1.7 μm) at 35 ℃ with a mobile phase consisting of acetonitrile-0.1% formic acid in aqueous solution gradient elution. After methodological validation, the lower quantification of 26 cathinone new psychoactive substances could reach 1.50−3.00 ng/L. Among these, 21 analytes fell within the concentration range of 1.50−375.0 ng/L, while 5 were detected in the range of 3.00−750.0 ng/L, the correlation coefficient was 0.99, within-and between-batch precision was less than 7.71% and 13.91%, respectively, and the extraction recoveries were higher than 92.64% . The method is simple, accurate, and sensitive, and can be used for cathinone detection and abuse monitoring.

CLC number: R917 Document code: A Article ID: 1000-5048(2025)-2-148-7

References

【1】
【1】
 
 
Journal of China Pharmaceutical University
Pages 148-154

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
DENG B, ZHU N, HUA Z, et al. Determination of 26 trace cathinones new psychoactive substances in sewage by HPLC-MS/MS. Journal of China Pharmaceutical University, 2025, 56(2): 148-154. https://doi.org/10.11665/j.issn.1000-5048.2024050603

1

Views

0

Downloads

0

Crossref

0

CSCD

Received: 06 May 2024
Published: 25 April 2025
© 2025 The Editorial Office of Journal of China Pharmaceutical University

This is an open access article under the CC BY-NC-ND license (https://creativecommons.org/licenses/by-nc-nd/4.0/).