AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline

Output-Feedback Optimal Control to Prevent Hypotension Associated with Labor Epidural Anesthesia

Zijian Yang* , Yuchen Dong* , Weinan Gao* ( ), Quan Na† ( ), Tengfei Liu* 
State Key Laboratory of Synthetical Automation for Process Industries, Northeastern University, Shenyang 110819, P. R. China
Department of Obstetrics and Gynecology, Shengjing Hospital of China Medical University, Shenyang 110004, P. R. China

This paper was recommended for publication in its revised form by Special Issue Editors, Jie Chen, Ben M Chen, and Zongli Lin.

Show Author Information

Abstract

In obstetric anesthesia, maintaining the stability of maternal hemodynamic systems is crucial for the safety of both maternal and fetal well-beings. To achieve this goal, manual infusion method is usually used that infuses phenylephrine to patients during surgery. However, traditional manual infusion method may lead to insufficient precision in the dosage. Although automatic control techniques may improve the accuracy of infusion, the implementation of closed-loop pressure control systems usually depends on the full measurement of states, which is hard or impossible to acquire. In this paper, based on auto-regressive with exogenous input models, an output-feedback optimal controller is developed that integrates a state reconstruction technique and an optimal state-feedback control policy. The proposed method effectively compensates for hypotension induced by bupivacaine through precise infusion of phenylephrine. Simulation results demonstrate that the proposed control method can efficiently regulate mean arterial pressure of patients.

References

【1】
【1】
 
 
Unmanned Systems
Pages 657-667

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Yang Z, Dong Y, Gao W, et al. Output-Feedback Optimal Control to Prevent Hypotension Associated with Labor Epidural Anesthesia. Unmanned Systems, 2026, 14(3): 657-667. https://doi.org/10.1142/S2301385026410049

2

Views

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 05 November 2025
Accepted: 08 December 2025
Published: 14 February 2026
© World Scientific Publishing Company