Ophthalmic surgical robot for precise retinal puncture and drug delivery

Chunbo Wang1,§Mengyao Liu1,§Zhao Li3,§He Zhang1 ( )Qun Wang2( )Yanhe Zhu1Liqiang Wang2Jie Zhao1
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, People’s Republic of China
Department of Ophthalmology, the Third Medical Center, Chinese PLA General Hospital, Beijing 100039, People’s Republic of China
School of Medicine, Nankai University, Tianjin, People’s Republic of China

§ These authors contributed equally to this work and should be considered co-first-author.

Show Author Information

Abstract

Subretinal injection (SI) is recognized as the most effective method for treating retinal degenerative and genetic diseases, enabling targeted delivery of therapeutic agents such as viral vectors or stem cells directly into the subretinal space (SRS). However, this procedure is typically performed under extremely constrained intraocular conditions, characterized by limited visualization, lack of tactile feedback, and the inherent fragility of retinal tissues, significantly increasing the risk of surgical complications and potential vision impairment. To overcome these challenges, an integrated force-sensing microneedle equipped with a flexible joint was developed and integrated into an ophthalmic surgical robotic system. This advanced system provides precise needle-tip pose control and real-time puncture force feedback. Leveraging these capabilities, force-guided autonomous retinal puncture was achieved, ensuring accurate and consistent drug delivery into the SRS. Comparative experiments conducted on live Bama pigs demonstrated the robotic system’s superiority over manual SI techniques, as evidenced by more stable puncture trajectories, smoother insertion velocities, precise insertion depths, and a greater than 90% reduction in average puncture force, despite respiratory and cardiac-induced disturbances, thus significantly enhancing surgical precision and minimizing the risk of iatrogenic retinal injury. Postoperative evaluations further validated that the robotic approach markedly reduced drug reflux into the vitreous cavity, underscoring its reliability and safety for SI.

References

【1】
【1】
 
 
International Journal of Extreme Manufacturing

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Wang C, Liu M, Li Z, et al. Ophthalmic surgical robot for precise retinal puncture and drug delivery. International Journal of Extreme Manufacturing, 2026, 8(1). https://doi.org/10.1088/2631-7990/ae00ff

413

Views

0

Downloads

2

Crossref

2

Web of Science

2

Scopus

0

CSCD

Received: 05 February 2025
Revised: 07 April 2025
Accepted: 29 August 2025
Published: 19 September 2025
© 2025 The Author(s).

Original content from this work may be used under the terms of the Creative Commons Attribution 4.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.