AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (5.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Paper | Open Access

Frequency multiplexed photothermal correlation tomography for non-destructive evaluation of manufactured materials

Pengfei Zhu1 , Rongbang Wang2, Koneswaran Sivagurunathan3, Stefano Sfarra4, Fabrizio Sarasini5, Clemente Ibarra-Castanedo1, Xavier Maldague1, Hai Zhang1,2 ( ), Andreas Mandelis3 ( )
Department of Electrical and Computer Engineering, Computer Vision and Systems Laboratory (CVSL), Laval University, Quebec G1V 0A6, Canada
Centre for Composite Materials and Structures (CCMS), Harbin Institute of Technology, Harbin 150001, People’s Republic of China
Center for Advanced Diffusion-Wave and Photoacoustic Technologies (CADIPT) and Institute for Advanced Non-Destructive and Non-Invasive Diagnostic Technologies (IANDIT), Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Canada
Department of Industrial and Information Engineering and Economics (DIIIE), University of L’Aquila, I-67100 L’Aquila (AQ), Italy
Department of Chemical Engineering Materials Environment & UDR INSTM, Sapienza University of Rome, Rome I-00184, Italy
Show Author Information

Abstract

Infrared thermography has been widely applied in real industrial inspection of aerospace, energy management systems, engines, and electric systems. However, two-dimensional imaging modality limits its development. Here, a technique named frequency multiplexed photothermal correlation tomography (FM-PCT) was developed to enable non-destructive and contactless cross-sectional imaging for manufactured material evaluation and characterization. By combining advantages of photothermal tomography and pulsed thermography, FM-PCT facilitates the generation of three-dimensional thermal images through temporal superposition (stacking) of two-dimensional images from sequential subsurface depths. FM-PCT image processing involves pulsed excitation signals to which frequency delay and matched filtering techniques are applied. Major features of FM-PCT are high-resolution three-dimensional tomographic imaging under low camera frame-rate conditions with self-correcting capability for diffusion (blurring) correction of subsurface images due to cross-correlation processing of individual frequencies in the Fourier decomposition spectrum of the excitation pulse. Furthermore, FM-PCT extends truncated-correlation photothermal coherence tomography from chirp and pulsed signals to more general linear heating sources. Lock-in thermography and x-ray computed tomography validation demonstrate that 3D FM-PCT imaging accurately reveals subsurface discontinuities/defects in solids despite the diffusive nature of thermal-wave imaging.

References

【1】
【1】
 
 
International Journal of Extreme Manufacturing

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhu P, Wang R, Sivagurunathan K, et al. Frequency multiplexed photothermal correlation tomography for non-destructive evaluation of manufactured materials. International Journal of Extreme Manufacturing, 2025, 7(3). https://doi.org/10.1088/2631-7990/ada837

586

Views

24

Downloads

39

Crossref

41

Web of Science

43

Scopus

0

CSCD

Received: 27 August 2024
Revised: 17 October 2024
Accepted: 08 January 2025
Published: 28 January 2025
© 2025 The Author(s).

Original content from this work may be used under the terms of the Creative Commons Attribution 4.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.