AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Paper | Open Access

On-line detection of additive concentrations in acidic copper plating solution for metal interconnection by an electrochemical microfluidic workstation

Yi Zhaoa,b,c,e,f, Ju-Xing Zenga,e, Jia-Qiang Yanga,b,c,e, Tao Songa,b,c,e,f, Ren Hub,e , Jian-Jia Sub,e, Bo Zhanga,e ( ), Fang-Zu Yanga,b,c,e ( ), Dongping Zhana,b,c,e ( ), Lianhuan Hana,d ( )
State Key Laboratory of Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, Fujian, China
National Engineering Research Center of Chemicals for Electronic Manufacturing (Reconstruction), Xiamen University, Xiamen 361005, Fujian, China
Engineering Research Center of Electrochemical Technologies of Ministry of Education, Xiamen 361005, Fujian, China
Department of Mechanical and Electrical Engineering, Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361005, Fujian, China
Department of Chemistry, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, Fujian, China
Discipline of Intelligent Instrument and Equipment, Xiamen University, Xiamen 361005, Fujian, China
Show Author Information

Abstract

On-line detection of additive concentrations in acidic copper (Cu) electroplating solution, including the suppressor, accelerator and leveler, is crucial for the industrial production of integrated circuit metal interconnections. For this purpose, a portable electrochemical microfluidic workstation (EMW) is developed. The polymer electrochemical microfluidic chip is designed and fabricated by 3D printing, in which a liquid mixer is integrated with an electrochemical microcell. The asymmetrically distributed herringbone microstructures in the microchannels (width: 400 μm, height: 300 μm, length: 4 cm) ensure the highly efficient mixture of solutions. In the electrochemical microcell, a 12.5 μm radius platinum ultramicroelectrode (Pt UME) acts as the working electrode. Based on the suppressing or accelerating effects of the additives on Cu electroplating, the calibration curves can be obtained by the stripping charge of electrodeposited Cu. Thus, the concentration of each additive in the acidic Cu electroplating solution can be detected on line and adjusted in time. The solution volume needed for each additive is approximately 220 μL. The detection error is lower than 10%, meeting the analytic requirements in industry. The automated EMW has the potential to replace the current manual cyclic voltammetry stripping (CVS) employed in lab analysis.

Graphical Abstract

References

【1】
【1】
 
 
Industrial Chemistry & Materials
Pages 607-617

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhao Y, Zeng J-X, Yang J-Q, et al. On-line detection of additive concentrations in acidic copper plating solution for metal interconnection by an electrochemical microfluidic workstation. Industrial Chemistry & Materials, 2025, 3(5): 607-617. https://doi.org/10.1039/d5im00073d

963

Views

4

Downloads

5

Crossref

5

Web of Science

Received: 06 May 2025
Accepted: 24 June 2025
Published: 26 June 2025
© 2025 The Author(s).

This article is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported Licence.