AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (9.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Original Paper | Open Access

Numerical and experimental study on the falling film flow characteristics with the effect of co-current gas flow in hydrogen liquefaction process

Chong-Zheng Suna, Yu-Xing Lib, Hui Hanb, Xiao-Yi Gengb, Xiao Lua( )
College of Energy Storage Technology, Shandong University of Science and Technology, Qingdao 266590, Shandong, China
College of Pipeline and Civil Engineering/Shandong Provincial Key Laboratory of Oil & Gas Storage and Transportation Safety, China University of Petroleum, Qingdao 266580, Shandong, China

Edited by Jie Hao and Meng-Jiao Zhou

Show Author Information

Abstract

Liquid hydrogen storage and transportation is an effective method for large-scale transportation and utilization of hydrogen energy. Revealing the flow mechanism of cryogenic working fluid is the key to optimize heat exchanger structure and hydrogen liquefaction process (LH2). The methods of cryogenic visualization experiment, theoretical analysis and numerical simulation are conducted to study the falling film flow characteristics with the effect of co-current gas flow in LH2 spiral wound heat exchanger. The results show that the flow rate of mixed refrigerant has a great influence on liquid film spreading process, falling film flow pattern and heat transfer performance. The liquid film of LH2 mixed refrigerant with column flow pattern can not uniformly and completely cover the tube wall surface. As liquid flow rate increases, the falling film flow pattern evolves into sheet-column flow and sheet flow, and liquid film completely covers the surface of tube wall. With the increase of shear effect of gas-phase mixed refrigerant in the same direction, the liquid film gradually becomes unstable, and the flow pattern eventually evolves into a mist flow.

References

【1】
【1】
 
 
Petroleum Science
Pages 1369-1384

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Sun C-Z, Li Y-X, Han H, et al. Numerical and experimental study on the falling film flow characteristics with the effect of co-current gas flow in hydrogen liquefaction process. Petroleum Science, 2024, 21(2): 1369-1384. https://doi.org/10.1016/j.petsci.2023.11.007

570

Views

8

Downloads

5

Crossref

4

Web of Science

6

Scopus

0

CSCD

Received: 28 April 2023
Revised: 12 October 2023
Accepted: 06 November 2023
Published: 16 November 2023
© 2023 The Authors.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).