Contrastive analysis of degradation behavior for WE43 magnesium alloy stents in cerebrovascular versus coronary hemodynamic environments

Chunhao Yua, Hongkang Zhangb,c,d, Yunong Shend, Yiming Huangc, Xinhao Yane, Ming Lib,f, Miaowen Jiangb, Yufeng Zhengd( ), Renjie Chaia,g,h,i( ), Xunming Jia,b,c( )
School of Life Science, Beijing Institute of Technology, Beijing 100081, China
Beijing Institute for Brain Disorders, Capital Medical University, Beijing 100069, China
Department of Neurology, Xuanwu Hospital, Capital Medical University, Beijing 100053, China
School of Materials Science and Engineering, Peking University, Beijing 100871, China
Amsino Medical Co., Ltd., Beijing 101520, China
Xuanwu Hospital, China-America Institute of Neurology, Capital Medical University, Beijing 100053, China
Department of Radiology, Zhuhai People’s Hospital, The Affiliated Hospital of Beijing Institute of Technology, Advanced Technology Research Institute, School of Life Science, Beijing Institute of Technology, Beijing 100081, China
State Key Laboratory of Bioelectronics, Department of Otolaryngology Head and Neck Surgery, Zhongda Hospital, School of Life Sciences and Technology, Advanced Institute for Life and Health, Jiangsu Province High-Tech Key Laboratory for Bio-Medical Research, Southeast University, Nanjing 210096, China
Co-Innovation Center of Neuroregeneration, Nantong University, Nantong 226019, China

Peer review under the responsibility of Chongqing University.

Show Author Information

Abstract

Cerebrovascular disease is the leading cause of death in China, and the long-term presence of non-degradable metal stents in neurointerventional therapy poses significant challenges. Biodegradable stents offer a promising solution, with magnesium (Mg) alloys emerging as a focal research area due to their favorable biocompatibility. However, most degradable Mg alloy stents are developed for cardiovascular applications, and their degradation behavior within the cerebral hemodynamic environment remains unclear. This study comparatively investigated the corrosion degradation of WE43 Mg alloy stents in the internal carotid artery (ICA), middle cerebral artery (MCA), and left anterior descending coronary artery (LAD), focusing on key hemodynamic characteristics distinguishing cerebral from coronary blood flow. Results demonstrated significantly higher blood flow velocities and consequently greater shear stresses acting on stents in cerebral arteries compared to coronary arteries. After 24 h, the remaining volume of the stent at the LAD site was 95.78%, at the MCA site it was 89.55%, and at the ICA site it was only 84.67%. The ICA location exhibited the fastest stent corrosion rate, developing deep pit-shaped defects on stent surfaces after 24 h. Corrosion products consisted predominantly of Mg3(PO4)2 and Mg(OH)2, with the degree of phosphorus (P) enrichment positively correlating with the corrosion rate. High shear stress compromised the integrity of the protective surface Mg(OH)2 layer, thus accelerating substrate exposure to corrosive media and shifting corrosion behavior from uniform to localized. This research provides experimental insights into the in-service degradation of biodegradable Mg alloys under complex hemodynamic conditions and offers theoretical support for designing next-generation intracranial stents with controlled degradation profiles.

References

【1】
【1】
 
 
Journal of Magnesium and Alloys

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Yu C, Zhang H, Shen Y, et al. Contrastive analysis of degradation behavior for WE43 magnesium alloy stents in cerebrovascular versus coronary hemodynamic environments. Journal of Magnesium and Alloys, 2026, 19. https://doi.org/10.1016/j.jma.2025.101974

4

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 19 September 2025
Revised: 11 November 2025
Accepted: 05 December 2025
Published: 08 March 2026
© 2026 Chongqing University.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)