Full Length Article | Open Access

A high-performance degradable Mg alloy suturing staple for single-arm oral stapling robot

Q.H. Wanga,1, S.S. Liangb,1, F.S. Yuanb( ), B.Y. Liua, J.Z. Yuc( ), W. Wangd, N. Fakhare, H.X. Lia( )
State Key Laboratory for Advanced Metals and Materials, University of Science and Technology Beijing, Beijing 100083, China
Center of Digital Dentistry, Peking University Hospital of Stomatology, Beijing 100081, China
College of Engineering, Peking University, Beijing 100871, China
School of Mechanical Engineering and Automation, Beihang University, Beijing 100191, China
Mechanical Engineering Department, Hamedan University of Technology, Hamedan, Iran

1 These authors contributed equally to this article.

Show Author Information

Abstract

Minimally invasive surgery (MIS) robots, such as single-arm stapling robots, are key to oral and maxillofacial surgery because they overcome space constraints in the oral cavity and deep throat. However, biodegradable suture staples should be developed for the single-arm stapling robots to avoid a secondary operation. For this aim, a new type of Mg-3Zn-0.2Ca-2Ag biodegradable alloy wire was developed in this study applied as suture staples. Its tensile strength, yield strength, and elongation are 326.1 MPa, 314.5 MPa, and 19.6%, respectively. Especially, the alloy wire attains the highest yield strength value reported among all the biodegradable Mg wires, which is mainly attributed to fine grain strengthening and second phase strengthening such as Mg2Zn11 nano phase strengthening. Moreover, the corrosion rate of this alloy wire in simulated body fluid (SBF) reaches 26.8 mm/y, the highest value among all the biodegradable Mg alloy wires reported so far, which is mainly from the intensified galvanic corrosion between the Ag17Mg54 phase and the Mg matrix. In vitro studies demonstrate that the alloy wire exhibits good blood compatibility and low cytotoxicity. The cone beam computed tomography (CBCT) data shows that the suture staple made of the Mg alloy wire provides better mechanical support in the early postoperative period. From the single arm robot tests, it confirms that suture staples can close the wound tightly and remain stable over time. This research provides a good material selection for the automated suturing in oral and throat surgery robots.

References

【1】
【1】
 
 
Journal of Magnesium and Alloys
Pages 4096-4118

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Wang Q, Liang S, Yuan F, et al. A high-performance degradable Mg alloy suturing staple for single-arm oral stapling robot. Journal of Magnesium and Alloys, 2024, 12(10): 4096-4118. https://doi.org/10.1016/j.jma.2023.06.009

846

Views

9

Downloads

11

Crossref

11

Web of Science

12

Scopus

3

CSCD

Received: 07 February 2023
Revised: 04 June 2023
Accepted: 04 June 2023
Published: 05 August 2023
© 2023 Chongqing University.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/) Peer review under responsibility of Chongqing University