AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (19.8 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Full Length Article | Open Access

Assessment of Mg(OH)2/TiO2 coating in the Mg-Ca-Zn alloy for improved corrosion resistance and antibacterial performance

Leonardo Hernándeza( ), Jesús Ramón-Sierrab, Montserrat Soria-Castroa, Ángel Bacelisa, Geonel Rodríguez-Gattornoa, Elizabeth Ortiz-Vázquezb, Gloria Acostac
Applied Physics Department, Center for Research and Advanced Studies of the National Polytechnic Institute (CINVESTAV-IPN), Carr. Ant. a Progreso km. 6, C.P. 97310, Merida, Yucatan, Mexico
Tecnológico Nacional de México/Instituto Tecnológico de Mérida. Av. Tecnológico s/n Km. 4.5 ant. Carr. Mérida-Progreso, C.P. 97118, Mérida, Yucatán, México
Facultad de Química, Universidad Nacional Autónoma de México (UNAM), Av. Universidad 3000, C.P. 04510, Coyoacán, CDMX, México
Show Author Information

Abstract

The high activity of metallic magnesium and alloys limits its potential in biomedical applications; in recent years, extensive efforts have been devoted to modulating this reactivity. In this work, we present Mg(OH)2 and TiO2 barrier coatings to reduce the degradation of magnesium alloy (Mg-Ca-Zn) surfaces. These coatings were deposited by the anodization method and the spin-coating technique, respectively. The anodized layer was coated with TiO2 generated from the hydrolysis of 3% weight of TTIP (Ti[OCH(CH3)2]4, Titanium(Ⅳ) isopropoxide) in 2-Propanol deposited by the spin-coating method. Studying the degradation in Ringer’s solution by electrochemical impedance spectroscopy and OCP revealed a 98% reduction in pittings in uncoated samples after 14 days of immersion. The pH measurements revealed that the TiO2 coating reduced the alkalization of the physiological environment, keeping the pH at 6.0 values. In vitro studies of two types of bacteria (E. coli and S. aureus) exhibited zones of inhibition in the agar and activity bactericidal (kill time test). The mechanisms behind the improved degradation resistance and enhanced antibacterial activity are presented and discussed here. Surface modification with Mg(OH)2/TiO2 coatings is a promising strategy to control the biodegradation of magnesium implants for bone regeneration.

References

【1】
【1】
 
 
Journal of Magnesium and Alloys
Pages 361-378

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Hernández L, Ramón-Sierra J, Soria-Castro M, et al. Assessment of Mg(OH)2/TiO2 coating in the Mg-Ca-Zn alloy for improved corrosion resistance and antibacterial performance. Journal of Magnesium and Alloys, 2023, 11(1): 361-378. https://doi.org/10.1016/j.jma.2022.08.005

435

Views

4

Downloads

20

Crossref

18

Web of Science

20

Scopus

2

CSCD

Received: 20 April 2022
Revised: 24 June 2022
Accepted: 18 August 2022
Published: 30 September 2022
© 2022 Chongqing University.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/) Peer review under responsibility of Chongqing University