AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (10.3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Full Length Article | Open Access

Quasi-in vivo corrosion behavior of AZ31B Mg alloy with hybrid MWCNTs-PEO/PCL based coatings

Morteza Daavaria,b( )Masoud AtapouraMarta MohedanobHugo Mora SánchezbJuan Rodríguez-HernándezcEndzhe MatykinabRaul ArrabalbAboozar Taherizadeha
Department of Materials Engineering, Isfahan University of Technology, 84156-83111 Isfahan, Iran
Departamento de Ingeniería Química y de Materiales, Facultad de Ciencias Químicas, Universidad Complutense, 28040 Madrid, Spain
Institute of Polymer Science and Technology (CSIC), Polymer Functionalization Group, Madrid 28006, Spain
Show Author Information

Abstract

This study investigated the effects of multi-walled carbon nanotubes (MWCNTs) and polycaprolactone (PCL) on the quasi-in vivo corrosion behavior of AZ31B Mg alloy treated by plasma electrolytic oxidation (PEO). Thin (~2 µm, PCTPCL4) and thick (~60 µm, PCTPCL6) PCL layers were applied only onto the MWCNTs-PEO coating (PCT) as it showed better corrosion performance. Findings reveal that incorporation of MWCNTs induced several structural and functional modifications in the PEO coating, such as increased roughness, a thicker inner barrier layer, and reduced hydrophilicity.

Quasi-in vivo corrosion testing was carried out under controlled temperature, pH, and fluid flow in simulated body fluid (SBF) by electrochemical impedance spectroscopy (EIS) and hydrogen evolution experiments. EIS results revealed that, after 48 h immersion, a diffusion process controlled hydration of the ceramic coatings. Comparison of the collected hydrogen after 15 days of immersion in the quasi-in vivo environment revealed that the PEO and PCT ceramic coatings decreased hydrogen generation by up to 74% and 91%, respectively, compared to non-coated alloy.

PCTPCL6 coating exhibited the lowest amount of collected hydrogen (0.2 mL/cm2). The thick PCL layer delayed the onset of substrate corrosion for at least 120 h, reducing the corrosion rate by 85% compared with the PCT.

References

【1】
【1】
 
 
Journal of Magnesium and Alloys
Pages 3217-3233

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Daavari M, Atapour M, Mohedano M, et al. Quasi-in vivo corrosion behavior of AZ31B Mg alloy with hybrid MWCNTs-PEO/PCL based coatings. Journal of Magnesium and Alloys, 2022, 10(11): 3217-3233. https://doi.org/10.1016/j.jma.2021.09.010

558

Views

3

Downloads

34

Crossref

33

Web of Science

36

Scopus

0

CSCD

Received: 30 June 2021
Revised: 05 September 2021
Accepted: 13 September 2021
Published: 09 October 2021
© 2021 Chongqing University.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/) Peer review under responsibility of Chongqing University