Short Communication | Open Access

Evaluation of adenosine triphosphate bioluminescence-based system in rooms occupied by patients with methicillin resistant Staphylococcus aureus

Anna Montgomerya,b( )Kimberly Hammerc,dDubert Guerrerod,eTze Shien Loc,d
Department of Research, San Francisco VA Medical Center, San Francisco, CA, USA
Department of Medicine, University of California San Francisco, San Francisco, CA, USA
Department of Medicine, University of North Dakota School of Medicine and Health Sciences, Grand Forks, ND, USA
Department of Infection Prevention, Fargo VA Healthcare System, Fargo, ND, USA
Department of Infection Prevention, Sanford Health, Fargo, ND, USA
Show Author Information

Abstract

Background

Adenosine triphosphate (ATP)-based monitoring systems can detect the amount of organic matter that remains on hospital surfaces after cleaning. We evaluated an ATP-based monitoring system in assessing contamination of high touched objects in rooms occupied by patients on methicillin resistant S. aureus precautions.

Methods

We compared the ATP to standard aerobic cultures as well as to gloved hand culture to predict risk of healthcare-worker hand contamination.

Results

More than a third of high touch object surfaces were measured unclean with ATP yet only reflects about 5% chance of contaminating healthcare-workers' hands.

Conclusions

Our study emphasizes the shortcomings of using the ATP system even in pathogen specific environment such as surfaces in methicillin resistant S. aureus rooms.

References

【1】
【1】
 
 
Infectious Medicine
Pages 217-220

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Montgomery A, Hammer K, Guerrero D, et al. Evaluation of adenosine triphosphate bioluminescence-based system in rooms occupied by patients with methicillin resistant Staphylococcus aureus. Infectious Medicine, 2022, 1(3): 217-220. https://doi.org/10.1016/j.imj.2022.08.002

1035

Views

3

Crossref

3

Web of Science

3

Scopus

Received: 16 February 2022
Revised: 14 June 2022
Accepted: 01 August 2022
Published: 06 August 2022
© 2022 The Author(s). Published by Elsevier Ltd on behalf of Tsinghua University Press.

This is an open access article under the CC BY-NC-ND license(http://creativecommons.org/licenses/by-nc-nd/4.0/)