Study on structure-borne noise characteristics and noise reduction of “integrated station-bridge” high-speed railway station

Bowen Houa( )Xinhao LiangaDi Wangb
School of Civil Engineering, Beijing Jiaotong University, Beijing 100044, China
China Railway Siyuan Survey and Design Group Co., Ltd., Wuhan 430063, China
Show Author Information

Abstract

Due to its high space utilization efficiency and overall advantages, the "integrated station-bridge" design is widely used in high-speed rail stations. However, compared to traditional separated station-bridge structures, the structure-borne noise generated by high-speed trains passing through these stations is more pronounced. To investigate the structure-borne noise radiation characteristics of these station designs, we developed a noise simulation model for the "integrated station-bridge" high-speed railway station and validated its reliability through comparison with test results. Building on this, we implemented the floating track slab between the track structure and the station platform to mitigate structure-borne noise. Furthermore, we examined the factors influencing the noise reduction effectiveness of the floating floor. The results indicated that train passages result in significant structure-borne noise issues in "integrated station-bridge" stations. The maximum sound pressure levels at the waiting hall and platform exceed 70 dB(A). After the implementation of the floating floor, the maximum sound pressure levels on each floor decreased by 11–14 dB(A). Additionally, increasing the thickness of the floating floor and reducing the stiffness of the steel spring bearings both enhanced the noise reduction effectiveness of the floating floor.

References

【1】
【1】
 
 
High-speed Railway
Pages 17-27

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Hou B, Liang X, Wang D. Study on structure-borne noise characteristics and noise reduction of “integrated station-bridge” high-speed railway station. High-speed Railway, 2025, 3(1): 17-27. https://doi.org/10.1016/j.hspr.2025.01.001

1

Views

0

Downloads

0

Crossref

0

Scopus

Received: 22 November 2024
Revised: 02 January 2025
Accepted: 09 January 2025
Published: 13 January 2025
© 2025 The Authors.