AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home hLife Article
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Article | Open Access

Construction and investigation of all-in-one microneedles complexed with functionalized polydiacetylene liposomes for improved in situ detection sensitivity

Jiarui Wang1,#Weimiao Li1,#Yan Chen3Meng Wu1Yan Shi1Jumin Lee2( )Ming Kong1( )
College of Marine Life Sciences, Ocean University of China, Shandong, China
Department of Materials Science and Engineering, Pohang University of Science and Technology, Gyeongsangbuk-do, Republic of Korea
Qingdao Technical College, Shandong, China

#These authors contributed equally to this work

Show Author Information

Highlights

● A novel label-free detection system is constructed with polydiacetylene liposomes and microneedle.

● The polydiacetylene liposomes complexed microneedles enable integration of target-sampling and detection in one platform.

● Polydiacetylene liposomes-complexed microneedles (PDA/MNs) significantly improve the detection sensitivity against various physiologic targets.

Abstract

Polydiacetylene (PDA) liposomes have been widely applied for detection due to their distinctive optical properties. However, the liquid phase in which PDA liposomes are dispersed generates several drawbacks, for instance, instability, compromise of detection sensitivity induced by dilution, and separation of target sampling and detection, making it inconvenient for application. In this paper, various functionalized PDA liposomes for detecting target were prepared, which were also immobilized into swelling microneedles to construct a solid-phase detection system. The PDA liposomes-complexed microneedles (PDA/MNs) enable the integration of target sampling and detection in one platform. The effects of the dispersing matrix phase on the detection sensitivity of PDA liposomes were systematically investigated from both environmental and chemical perspectives. PDA/MNs exhibited higher sensitivity than their counterparts in liquid phase. PDA/MNs were optimized and validated for lead ion (Pb2+) and sialic acid (SA) detections. For Pb2+ detection, the limit of detection (LOD) of the PDA/MNs was 13.7 μM and 2.5 times lower than the liquid phase. For SA detection, the LOD of the PDA/MNs was 0.83 μM and 1.7 times lower than the liquid phase. The results suggested that such PDA/MNs were validated to provide a label-free, stable, sensitive, and convenient tool in an all-in-one manner for physiologic target detection.

Graphical Abstract

References

【1】
【1】
 
 
hLife
Pages 514-526

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Wang J, Li W, Chen Y, et al. Construction and investigation of all-in-one microneedles complexed with functionalized polydiacetylene liposomes for improved in situ detection sensitivity. hLife, 2024, 2(10): 514-526. https://doi.org/10.1016/j.hlife.2024.07.005

563

Views

5

Crossref

Received: 16 April 2024
Revised: 09 July 2024
Accepted: 11 July 2024
Published: 19 July 2024
© 2024 The Authors.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).