AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (696.3 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Open Access

Dynamic microwave-assisted extraction combined with liquid phase microextraction based on the solidification of a floating drop for the analysis of organochlorine pesticides in grains followed by GC

Guijie Lia,b, Xu Zhanga, Tingting Liua, Hongxiu Fana, Hongcheng Liua, Shangyu Lib, Dawei Wanga( ), Lan Dingc( )
College of Food Science and Engineering, Jilin Agricultural University, Changchun 130118, China
Jilin Province Product Quality Supervision and Inspection Institute, Changchun 130103, China
College of Chemistry, Jilin University, 2699 Qianjin Street, Changchun 130012, China

Peer review under responsibility of KeAi Communications Co., Ltd

Show Author Information

Abstract

A convenient, cost-effective and fast method using dynamic microwave-assisted extraction and liquid phase microextraction based on the solidification of a floating drop was proposed to analyze organochlorine pesticides in grains including rice, maize and millet. Twelve samples can be processed simultaneously in the method. During the extraction process, 10% acetonitrile-water solutions containing 110 μL of n-hexadecane were used to extract organochlorine pesticides. Subsequently, 1.0 g sodium chloride was placed in the extract, and then centrifuged and cooled. The n-hexadecane drops containing the analytes were solidified and transferred for determination by gas chromatography-electron capture detector without any further filtration or cleaning process. Limits of detection for organochlorine pesticides were 0.97–1.01 μg/kg and the RSDs were in the range of 2.6%–8.5%. The developed technology has succeeded in analyzing six real grains samples and the recoveries of the organochlorine pesticides were 72.2%–94.3%. Compared with the published extraction methods, the developed method was used to analyze organochlorine pesticides in grains, being more environmentally friendly, which is suitable for the daily determination of organochlorine pesticides.

References

【1】
【1】
 
 
Food Science and Human Wellness
Pages 375-382

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Li G, Zhang X, Liu T, et al. Dynamic microwave-assisted extraction combined with liquid phase microextraction based on the solidification of a floating drop for the analysis of organochlorine pesticides in grains followed by GC. Food Science and Human Wellness, 2021, 10(3): 375-382. https://doi.org/10.1016/j.fshw.2021.02.029

1110

Views

123

Downloads

11

Crossref

10

Web of Science

12

Scopus

4

CSCD

Received: 06 August 2020
Revised: 28 September 2020
Accepted: 29 September 2020
Published: 16 April 2021
© 2021 Beijing Academy of Food Sciences. Production and hosting by Elsevier B.V. on behalf of KeAi Communications Co., Ltd.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).