AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Original Research | Open Access

Tap water microbiome shifts in secondary water supply for high-rise buildings

Manjie Lia,bZhaowei Liub( )Yongcan Chenb
Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, PR China
State Key Laboratory of Hydroscience and Engineering, Tsinghua University, Beijing, 100084, PR China
Show Author Information

Abstract

In high-rise buildings, secondary water supply systems (SWSSs) are pivotal yet provide a conducive milieu for microbial proliferation due to intermittent flow, low disinfectant residual, and high specific pipe-surface area, raising concerns about tap water quality deterioration. Despite their ubiquity, a comprehensive understanding of bacterial community dynamics within SWSSs remains elusive. Here we show how intrinsic SWSS variables critically shape the tap water microbiome at distal ends. In an office setting, distinct from residential complexes, the diversity in piping materials instigates a noticeable bacterial community shift, exemplified by a transition from α-Proteobacteria to γ-Proteobacteria dominance, alongside an upsurge in bacterial diversity and microbial propagation potential. Extended water retention within SWSSs invariably escalates microbial regrowth propensities and modulates bacterial consortia, yet secondary disinfection emerges as a robust strategy for preserving water quality integrity. Additionally, the regularity of water usage modulates proximal flow dynamics, thereby influencing tap water's microbial landscape. Insights garnered from this investigation lay the groundwork for devising effective interventions aimed at safeguarding microbiological standards at the consumer's endpoint.

References

【1】
【1】
 
 
Environmental Science and Ecotechnology
Article number: 100413

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Li M, Liu Z, Chen Y. Tap water microbiome shifts in secondary water supply for high-rise buildings. Environmental Science and Ecotechnology, 2024, 20: 100413. https://doi.org/10.1016/j.ese.2024.100413

593

Views

14

Crossref

12

Web of Science

15

Scopus

Received: 29 September 2023
Revised: 07 March 2024
Accepted: 08 March 2024
Published: 16 March 2024
© 2024 The Authors. Chinese Society for Environmental Sciences, Harbin Institute of Technology, Chinese Research Academy of Environmental Sciences.

This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).