Discover the SciOpen Platform and Achieve Your Research Goals with Ease.
Search articles, authors, keywords, DOI, etc.
Aviation kerosene RP-3 is extensively used in China. This paper details the measurement of the density of Chinese aviation kerosene RP-3 employing the flow method under high-pressure and high-temperature conditions. The methodology utilizes circular tubes with two different diameters. The density of aviation kerosene RP-3 was experimentally measured for the first time within a pressure range from 6 MPa to 8 MPa and a temperature range from 323 K to 783 K, with a maximum relative uncertainty of 0.35%. The experimental setup used n-decane for calibration, achieving an average calibration error of 0.91%. The data indicate that the density of RP-3 ranges from 764 kg/m3 to 247 kg/m3 under the tested conditions. The results show that the density of kerosene RP-3 decreases with an increase in temperature at a constant pressure, and at a given temperature, a higher pressure results in a higher density. Polynomial fitting was applied to the data, resulting in the average absolute deviation of 1.09%, 0.80%, and 0.76% at different pressures of 6, 7, and 8 MPa, respectively.
This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).