Effects of mid-passage gap with a variable surface angle on a turbine vane endwall’s aerothermal and film cooling performances

Zhiyu LI, Kaiyuan ZHANG( ), Zhigang LI, Jun LI
Institute of Turbomachinery, Xi’an Jiaotong University, Xi’an 710049, China

Peer review under responsibility of Editorial Committee of CJA.

Show Author Information

Abstract

The mid-passage gap is an inevitable structure in a vane passage due to turbine vanes being manufactured individually. The coolant from this gap is able to prevent hot mainstream ingression and provide cooling protection for the endwall. A novel idea of enlarging the endwall’s coverage area and reducing the endwall’s thermal load by applying the mid-passage gap with variable surface angles is carried out in this paper. The endwall’s aerothermal and film cooling performances under four mid-passage gap modes at three typical mass flow ratio conditions are numerically investigated. Results indicate that under the traditional mid-passage mode, the coolant flows into the mainstream with a perpendicular incidence angle and can’t stick to the endwall. Thus, cooling failure occurs, and the endwall’s thermal load is badly increased. The film cooling level at the suction-side endwall is improved when applying the mid-passage gap of a 45° surface angle due to the secondary vortex being suppressed. In addition, when applying the mid-passage gap of a 135° surface angle, the horseshoe vortex is pushed away, and the coverage area at the pressure-side endwall is enlarged significantly. The best film cooling performance is achieved when the upstream surface angle is 135° and the downstream surface angle is 45° due to the adiabatic film cooling effectiveness being increased at both the pressure- and suction-side endwall. When the mass flow ratio is 1.5%, the coverage area is enlarged by 43%, and the area-averaged adiabatic film cooling effectiveness is increased by 37%, when compared with those under the traditional mid-passage mode.

References

【1】
【1】
 
 
Chinese Journal of Aeronautics
Pages 20-37

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LI Z, ZHANG K, LI Z, et al. Effects of mid-passage gap with a variable surface angle on a turbine vane endwall’s aerothermal and film cooling performances. Chinese Journal of Aeronautics, 2024, 37(6): 20-37. https://doi.org/10.1016/j.cja.2024.03.041

777

Views

5

Crossref

10

Web of Science

12

Scopus

1

CSCD

Received: 14 June 2023
Revised: 27 June 2023
Accepted: 14 August 2023
Published: 30 March 2024
© 2024 Chinese Society of Aeronautics and Astronautics.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).