AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Full Length Article | Open Access

Influence of bolt dynamic installation on topography characteristics and mechanical behaviors of CFRP interference-fit bolted joints

Xiaohe WANGa, Zengqiang CAOa,b( ), Yuehaoxuan WANGa, Yingjiang GUOa
School of Mechanical Engineering, Northwestern Polytechnical University, Xi’an 710072, China
NPU Xuhang Electromagnetic Technology Co., Ltd., Xi’an 710100, China

Peer review under responsibility of Editorial Committee of CJA

Show Author Information

Abstract

As the controlled research of Dynamic Installation (DI) and Static Installation (SI), a new interference installation method was developed based on electromagnetic loading to enhance the mechanical properties of composite structures. Four different interference-fit sizes were considered, ranging from a net fit to 2.0%. The experiments were conducted to evaluate the installation resistance and the mechanical behavior of the joint under external loads. Meanwhile, an FEA model to model the stress distribution and damage behavior of the bolt-hole contact interface was established. The load–displacement curve and damage modes of experiments were used to verify the FEA results. The results show that the installation resistance during DI process was remarkably lower than that of SI process corresponding to all interference-fit sizes, and the stress amplitudes induced by interference were larger and widely distributed. The damage of the hole wall was positively correlated with interference fit size, but DI can significantly reduce the damage compared to SI. In performance tests, DI enhanced the static bearing capacity and extended longer fatigue life of the joints than SI. DI methods can be an effective way to achieve highly reliable interference joints in composite structures.

References

【1】
【1】
 
 
Chinese Journal of Aeronautics
Pages 482-500

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
WANG X, CAO Z, WANG Y, et al. Influence of bolt dynamic installation on topography characteristics and mechanical behaviors of CFRP interference-fit bolted joints. Chinese Journal of Aeronautics, 2024, 37(2): 482-500. https://doi.org/10.1016/j.cja.2023.11.004

1133

Views

39

Crossref

34

Web of Science

37

Scopus

4

CSCD

Received: 03 February 2023
Revised: 05 March 2023
Accepted: 02 April 2023
Published: 09 November 2023
© 2023 Chinese Society of Aeronautics and Astronautics.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).