AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Full Length Article | Open Access

Direct thrust test and asymmetric performance of porous ionic liquid electrospray thruster

Yuntao GUOa, Wei SUNa, Zhenning SUNb, Zhiwen WUa( ), Jianwu HEc,d, Chao YANGc,d, Ningfei WANGa
School of Aerospace Engineering, Beijing Institute of Technology, Beijing 100081, China
Beijing Institute of Electronic System Engineering, Beijing 100039, China
Key Laboratory of Microgravity, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China
School of Engineering Sciences, University of Chinese Academy of Sciences, Beijing 100049, China

Peer review under responsibility of Editorial Committee of CJA.

Show Author Information

Abstract

In order to meet the demand of CubeSats for low power and high-performance micro-propulsion system, a porous ionic liquid electrospray thruster prototype is developed in this study. 10 × 10 conical emitter arrays are fabricated on an area of 3.24 cm2 by computer numerical control machining technology. The propellant is 1-ethyl-3-methylimidazolium tetrafluoroborate. The overall dimension of the assembled prototype is 3 cm × 3 cm × 1 cm, with a total weight of about 15 g (with propellant). The performance of this prototype is tested under vacuum. The results show that it can work in the voltage range of ±2.0 kV to ±3.0 kV, and the maximum emission current and input power are about 355 μA and 1.12 W. Time of Flight (TOF) mass spectrometry results show that cationic monomers and dimers dominate the beam in positive mode, while a higher proportion of higher-order solvated ion clusters in negative mode. The maximum specific impulse is 2992 s in positive mode and 849 s in negative mode. The thrust is measured in two methods: one is calculated by TOF results and the other is directly measured by high-precision torsional thrust stand. The thrust (T) obtained by these two methods conforms to a certain scaling law with respect to the emission current (Iem) and the applied voltage (Vapp), following the scale of T ~ IemVapp0.5, and the thrust range is from 2.1 μN to 42.6 μN. Many thruster performance parameters are significantly different in positive and negative modes. We speculate that due to the higher solvation energy of the anion, more solvated ion clusters are formed rather than pure ions under the same electric field. It may help to improve thruster performance if porous materials with smaller pore sizes are used as reservoirs. Although there are still many problems, most of the performance parameters of ILET-3 are good, which can theoretically meet the requirements of CubeSats for micro-propulsion system.

References

【1】
【1】
 
 
Chinese Journal of Aeronautics
Pages 120-133

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
GUO Y, SUN W, SUN Z, et al. Direct thrust test and asymmetric performance of porous ionic liquid electrospray thruster. Chinese Journal of Aeronautics, 2023, 36(4): 120-133. https://doi.org/10.1016/j.cja.2022.09.007

1131

Views

52

Crossref

49

Web of Science

56

Scopus

13

CSCD

Received: 14 March 2022
Revised: 07 April 2022
Accepted: 13 May 2022
Published: 11 September 2022
© 2022 Chinese Society of Aeronautics and Astronautics.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).