Calibration method of quartz accelerometer on dynamic centrifuge

Yingbo SUNShunqing RENChanghong WANG( )
School of Astronautics, Harbin Institute of Technology, Harbin 150001, China

Peer review under responsibility of Editorial Committee of CJA.

Show Author Information

Abstract

This paper proposes a novel method for calibrating error coefficients of the quartz accelerometer faster on the dynamic centrifuge, which can generate a continuous dynamic acceleration excitation. Firstly, working principle and structure of the dynamic centrifuge are analyzed, the error sources and the uncertainty of the dynamic centrifuge are expounded, and relevant coordinate systems are established. Then, according to the characteristics of the input specific forces and the propagating methods of the error sources, the accurate input specific forces acted on the input reference axes of accelerometer are obtained. Based on the calibration error model of the accelerometer, the corresponding dynamic calibration method is proposed. Finally, the second-order and high-order coefficients of the acceleration error model are calibrated, and the calibration precision of the coefficients is analyzed. Compared with traditional calibration methods, the method proposed in this paper not only greatly enhances the calibration efficiency by reducing the installing positions of the accelerometer, but also separates the centrifuge errors from the outputs of the accelerometer, which improves the accuracy and efficiency of the calibration method simultaneously.

References

【1】
【1】
 
 
Chinese Journal of Aeronautics
Pages 262-272

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
SUN Y, REN S, WANG C. Calibration method of quartz accelerometer on dynamic centrifuge. Chinese Journal of Aeronautics, 2022, 35(6): 262-272. https://doi.org/10.1016/j.cja.2021.07.021

328

Views

10

Crossref

10

Web of Science

15

Scopus

5

CSCD

Received: 20 January 2021
Revised: 15 February 2021
Accepted: 17 March 2021
Published: 21 October 2021
© 2021 Chinese Society of Aeronautics and Astronautics.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).