Effect of system response on partial surge initiated instability in a transonic axial flow compressor

Tianyu PANaZhaoqi YANa,bDakun SUNbSimin LIbMengzong ZHENGb( )Qiushi LIa,b,c
Reserach Institute of Aero-Engine, Beihang University, Beijing 100083, China
School of Energy and Power Engineering, Beihang University, Beijing 100083, China
Key Laboratory of Fluid and Power Machinery, Ministry of Education, Xihua University, Chengdu 610039, China

Peer review under responsibility of Editorial Committee of CJA.

Show Author Information

Abstract

Partial surge is a type of instability inception in transonic compressors and occurs in the form of axisymmetric low-frequency disturbances localized in the hub region. Previous studies illustrate that the frequency of partial surge is set by the Helmholtz frequency of the entire system, which motivates to propose a hypothesis that the system response performs an important role in the formation of partial surge. For further verification, a series of experiments are conducted to explore the link between the propagating of the partial surge and the system feedback in this study. In the first case, an additional test point is set on the wall of the plenum to detect the system response. Combining the flow behaviors inside the plenum with the disturbances in the rotor tip and stator hub/tip regions, the effects of the system feedback on the occurrence of the continuous disturbances and the rotating stall cells are illustrated. In the second case, a screen is mounted at the compressor outlet to prevent positive feedback from the plenum. The experimental results demonstrate that in the absence of system feedback, it is the occurrence of spike-type stall inception that leads to the flow instability instead of that of partial surge. In addition, three flow phenomena in the second case are discussed, including the occurrence of the single pulse, the unstable process during the stall evolution and the switch of instability inception.

References

【1】
【1】
 
 
Chinese Journal of Aeronautics
Pages 117-127

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
PAN T, YAN Z, SUN D, et al. Effect of system response on partial surge initiated instability in a transonic axial flow compressor. Chinese Journal of Aeronautics, 2022, 35(2): 117-127. https://doi.org/10.1016/j.cja.2020.12.043

482

Views

11

Crossref

9

Web of Science

12

Scopus

4

CSCD

Received: 29 September 2020
Revised: 15 November 2020
Accepted: 30 November 2020
Published: 20 March 2021
© 2021 Chinese Society of Aeronautics and Astronautics and Beihang University.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).