AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (19.5 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline

Phase Contrast Micro-Computed Tomography of Biological Sample at SSRF

Rongchang CHEN1,2,3Honglan XIE1,3Luigi Rigon3Guohao DU1Edoardo Castelli2,3Tiqiao XIAO1( )
Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204, China
Department of Physics, University of Trieste, Trieste 34127, Italy
INFN, Sezione di Trieste, Trieste 34012, Italy
Show Author Information

Abstract

In line X-ray phase contrast micro-computed tomography (IL-XPCT), which can be implemented at third generation synchrotron radiation sources or by using a micro-focus X-ray tube, is a powerful technique for non-destructive, high-resolution investigations of a broad variety of materials. At the Shanghai Synchrotron Radiation Facility (SSRF), the X-ray Imaging and Biomedical Applications Beamline was built and started regular user operation in May 2009. Both qualitative (without phase retrieval) and quantitative (with phase retrieval) three-dimensional IL-XPCT experimental techniques have been established at the beamline. IL-XPCT experiments of a test sample (plastic pipes) used to evaluate the technique, and of a biological sample (locust) at the beamline are reported. Two series of images, qualitative and quantitative, including tomographic slices and three-dimensional rendering images were obtained. In qualitative images, there is a strong edge-enhancement which leads to very clear sample contours, while in quantitative images, the edge-enhancement fades but quantitative measurement of sample’s phase information could be achieved. The experiments demonstrate that the combination of qualitative and quantitative images is useful for biological sample studies.

References

【1】
【1】
 
 
Tsinghua Science and Technology
Pages 102-107

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
CHEN R, XIE H, Rigon L, et al. Phase Contrast Micro-Computed Tomography of Biological Sample at SSRF. Tsinghua Science and Technology, 2010, 15(1): 102-107. https://doi.org/10.1016/S1007-0214(10)70016-X

105

Views

1

Downloads

4

Crossref

N/A

Web of Science

7

Scopus

19

CSCD

Received: 09 October 2009
Revised: 28 December 2009
Published: 01 February 2010
© Tsinghua University Press 2010