Quantitative Accuracy Assessment and Optimization of SPECT Geometrical Calibration

Tianyu MA( )Yinbin MIAORutao YAOTiantian DAIXiao DENG
Key Laboratory of Particle & Radiation Imaging of Ministry of Education, Department of Engineering Physics, Tsinghua University, Beijing 100084, China
Department of Nuclear Medicine, State University of New York at Buffalo, Buffalo, New York 14214, USA
Show Author Information

Abstract

Accurate geometrical calibration is critical to obtaining high resolution and artifact free reconstructed images for modern animal single photon emission computed tomography (SPECT) systems. Although there have been many published works on the calibration of various SPECT systems, few studies have been done to evaluate the efficacy of the proposed calibration methods in a quantitative manner. This paper presents a numerical method to assess both the uniqueness and the quantitative accuracy of SPECT calibration, which is based on analyzing the singular value decomposition (SVD) components of the Jacobian matrix from a least-square cost function of the calibration. The proposed method is firstly validated by applying it to the calibration of a single pinhole SPECT system and comparing the results with those derived using a published method, and is then used to optimize the calibration setup for a slit-slat SPECT system. With the proposed method, a minimum required number of point source projections to achieve the desired calibration accuracy can be estimated and used as figure-of-merit to evaluate the goodness of a calibration setup. An inverse-square relationship between the calibration accuracy and the number of sampled projections is revealed. Optimal calibration setup is determined through an exhaustive search among all the possibilities of point source arrangements under certain conditions. We demonstrate that for the studied system, the best calibration accuracy is achieved by arranging the point source over the edge of FOV with evenly-spaced angular positions. Point source experiments were conducted to validate the proposed method.

References

【1】
【1】
 
 
Tsinghua Science and Technology
Pages 96-101

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
MA T, MIAO Y, YAO R, et al. Quantitative Accuracy Assessment and Optimization of SPECT Geometrical Calibration. Tsinghua Science and Technology, 2010, 15(1): 96-101. https://doi.org/10.1016/S1007-0214(10)70015-8

102

Views

1

Downloads

1

Crossref

N/A

Web of Science

1

Scopus

19

CSCD

Received: 16 October 2009
Revised: 16 December 2009
Published: 01 February 2010
© Tsinghua University Press 2010