Emission-Based Scatter Correction in SPECT Imaging

Chuanyong Bai( )Hetal BablaRichard Conwell
Digirad Corporation, Poway, CA 92064, USA
Show Author Information

Abstract

Scatter correction in single photon emission computed tomography (SPECT) has been focused on either using multiple-window acquisition technique or the scatter modeling technique in iterative image reconstruction. We propose a technique that uses only the emission data for scatter correction in SPECT. We assume that the scatter data can be approximated by convolving the primary data with a scatter kernel followed by the normalization using the scatter-to-primary ratio (SPR). Since the emission data is the superposition of the primary data and the scatter data, the convolution normalization process approximately results in the sum of the scatter data and a convolved version of scatter data with the kernel. By applying a proper scaling factor, we can make the estimation approximately equal to or less than the scatter data anywhere in the projection domain. Phantom and patient cardiac SPECT studies show that using the proposed emission-based scatter estimation can effectively reduce the scatter-introduced background in the reconstructed images. And additionally, the computational time for scatter correction is negligible as compared to no scatter correction in iterative image reconstruction.

References

【1】
【1】
 
 
Tsinghua Science and Technology
Pages 1-10

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Bai C, Babla H, Conwell R. Emission-Based Scatter Correction in SPECT Imaging. Tsinghua Science and Technology, 2010, 15(1): 1-10. https://doi.org/10.1016/S1007-0214(10)70001-8

80

Views

1

Downloads

3

Crossref

N/A

Web of Science

3

Scopus

19

CSCD

Received: 14 October 2009
Revised: 20 December 2009
Published: 01 February 2010
© Tsinghua University Press 2010