AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Original Article | Open Access

Effect of Sampling Frequency on a Unilateral Isometric Hamstring Strength Assessment Using Force Plates

Nicholas J Ripley1 ( )J. J. McMahon1P Comfort1,2
School of Health and Society, University of Salford, Salford, UK
School of Medical and Health Sciences, Edith Cowan University, Joondalup, Australia
Show Author Information

Abstract

The purpose of this study was to determine the effect of sampling frequency on the 90–90° (90-degrees hip and knee flexion) isometric hamstring assessment. Thirty-three elite female soccer players (age: 18.7 ± 3.7 years; height: 158.3 ± 5.9 cm; body mass: 62.8 ± 5.5 kg) performed three unilateral trials on a single occasion of the 90–90° isometric hamstring assessment. Force-time data were collected using force plates at 1000 Hz and down sampled to 500-, 250-, and 100 Hz. Peak force (N), force (N) at 100- and 200 ms and average rate of force development (aRFD) (N/s) over a 100- and 200 ms epoch were calculated. A repeated measures of analysis of variance and effect size was used to compare means. Excellent absolute and good relative reliability was observed for peak force across all sampling frequencies. Force at 100- and 200 ms and aRFD over 100 ms and 200 ms resulted poor-moderate relative reliability and poor-excellent absolute reliability. No significant trivial differences were observed for peak force between sampling frequencies (P > 0.05, Cohen’s d = 0.02–0.12). A significant difference (P < 0.001) was identified in 500, 250 and 100 Hz, with small-moderate and small-large increases in force at set time points and aRFD, respectively, in comparison to 1000 Hz (d = 0.21–2.00). Higher sampling frequencies (> 500 Hz) reduces the reliability of time dependent force characteristics, with minimal effect on peak force. Regular monitoring of peak force can be performed with higher sampling frequencies, but lower sampling frequencies would be beneficial to collect reliable rapid-force generating measures.

References

【1】
【1】
 
 
Journal of Science in Sport and Exercise
Pages 292-300

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Ripley NJ, McMahon JJ, Comfort P. Effect of Sampling Frequency on a Unilateral Isometric Hamstring Strength Assessment Using Force Plates. Journal of Science in Sport and Exercise, 2026, 8(3): 292-300. https://doi.org/10.1007/s42978-024-00277-w

2

Views

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 23 August 2023
Accepted: 04 January 2024
Published: 12 April 2024
© The Author(s) 2024

This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.