Comparison of the VO2 Master Pro and Cosmed K5 During Walking, Jogging, and Running

Alex Toulouse1 Dustin Joubert2Gary Oden1Patrick R. Davis1 ( )
Department of Kinesiology, Sam Houston State University, Huntsville, TX, USA
Department of Kinesiology and Health Science, Stephen F. Austin University, Nacogdoches, TX, USA
Show Author Information

Abstract

Aim

Portable devices that accurately detect the composition of expired gases and changes in VO2 open new possibilities in research methodology and accessibility.

Purpose

The purpose of this study was to compare the oxygen consumption (VO2) measurements of the VO2 Master Pro (VM) to the Cosmed K5 (K5) during walking, jogging, and running in field and lab conditions.

Methods

Twelve proficient runners, with a current 10 k pace of ≥ 11.29 km/h, performed 3 matched intervals at 3 different speeds (4.82, 8.05, 11.29 km/h) on a treadmill and on an outdoor track. An airflow test was also performed on both devices by pumping air through the devices using a 3 L syringe timed to a metronome at 15, 25, and 35 beats/min.

Results

The VM did not report walking data for most participants. During treadmill running, there were significant differences in VO2 (47.86 ± 3.94 vs. 29.56 ± 4.15 mL/kg/min), ventilation (Ve) (71 vs. 57 mL/min), and tidal volume (TV) (1.89 vs. 1.56 L) between the K5 and VM respectively (P < 0.05). Outdoor analysis also showed significant differences between devices in VO2, Ve, and TV (P < 0.05). The airflow test showed significant differences between the devices in Ve and TV (P < 0.05).

Conclusion

These results suggest that there are significant discrepancies between the K5 and the VM, likely due to differences in TV measurement.

References

【1】
【1】
 
 
Journal of Science in Sport and Exercise
Pages 119-127

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Toulouse A, Joubert D, Oden G, et al. Comparison of the VO2 Master Pro and Cosmed K5 During Walking, Jogging, and Running. Journal of Science in Sport and Exercise, 2022, 4(2): 119-127. https://doi.org/10.1007/s42978-021-00146-w

1852

Views

4

Crossref

7

Web of Science

7

Scopus

0

CSCD

Received: 06 October 2020
Accepted: 09 October 2021
Published: 19 November 2021
© Beijing Sport University 2021