AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.5 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Advanced thermal insulation strategies for liquid hydrogen storage tanks in Martian environments

Yang Yu1Fushou Xie1,2( )Yanzhong Li1,2
Institute of Refrigeration and Cryogenic Engineering, Xi’an Jiaotong University, Xi’an 710049, China
State Key Laboratory of Technologies in Space Cryogenic Propellants, Beijing 100028, China
Show Author Information

Abstract

Liquid hydrogen (LH2) is a highly preferred fuel for propelling large-ton Martian landers. Currently, composite insulation structures (CISs), consisting of multilayer insulation (MLI) and spray-on foam insulation (SOFI) are used for the thermal protection of cryogenic propellant tanks. However, the Martian environment poses significant challenges for the thermal protection of LH2 tanks, primarily because of the presence of rarefied carbon dioxide (CO2). CO2 can condense within the MLI microchannels, leading to significant deterioration in the insulation performance of CIS. This study investigates this unique phenomenon occurring on Mars. Two thermal-insulation schemes are designed for potential applications in Martian landers. Numerical models are developed to predict the insulation performance of CIS on Mars by coupling CO2 condensation and conduction calculations within microchannels. Several key findings emerge: (1) The heat leakage decreases by 82.22% as SOFI thickness increases from 5 to 50 mm. (2) The heat leakage initially rises sharply, and then increases gradually with ambient Martian temperature. (3) The insulation performance deteriorates rapidly and then stabilizes as the number of MLI layers increases, but the heat leakage of CIS exceeds 10 W/m2. (4) A new type of insulation scheme (NIS) aimed at solving the issue in finding (3) is designed for the Mars lander by prioritizing the minimum weight which results in an NIS heat leakage of 0.298 W/m2—two to four orders of magnitude lower than that of CISs. These findings provide valuable technical insights into enhancing the thermal protection of LH2 propellant tanks.

Graphical Abstract

References

【1】
【1】
 
 
Astrodynamics
Pages 837-854

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Yu Y, Xie F, Li Y. Advanced thermal insulation strategies for liquid hydrogen storage tanks in Martian environments. Astrodynamics, 2025, 9(6): 837-854. https://doi.org/10.1007/s42064-024-0248-y

1626

Views

41

Downloads

1

Crossref

2

Web of Science

2

Scopus

0

CSCD

Received: 30 January 2024
Accepted: 30 October 2024
Published: 17 November 2025
© Tsinghua University Press 2025