AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Original Paper

Thunderstorm Structure and Lightning Properties in South China and over the South China Sea: A Comparative Study

Department of Atmospheric and Oceanic Sciences and Institute of Atmospheric Sciences, Fudan University, Shanghai 200438
State Key Laboratory of Severe Weather Science and Technology, Chinese Academy of Meteorological Sciences,China Meteorological Administration (CMA), Beijing 100081
CMA–FDU Joint Laboratory of Marine Meteorology and Shanghai Frontiers Science Center of Atmosphere–Ocean Interaction, Shanghai 200438
Show Author Information

Abstract

Using lightning data from the Lightning Imaging Sensor onboard the Tropical Rainfall Measurement Mission satellite, together with cloud and precipitation property data extracted from the Radar Precipitation Feature dataset, this study investigated the statistical characteristics of thunderstorm structure and lightning properties over land (South China) and the South China Sea (SCS) during 1998–2014. The objective was to compare thunderstorm structural differences and explore the impact of thunderstorm structure on lightning properties between land and transitional water areas to the deep ocean. The results indicate that the lightning activity in South China is notably more intense than that over the SCS, with the average frequency and density of lightning in South China approximately doubling the values of those over the SCS. Although the mean flash duration is similar in both regions, lightning over the SCS exhibits larger average values for flash length, footprint, and radiance. Additionally, the horizontal scale and the verti-cal extension of thunderstorms over the SCS are substantially larger than those in South China, i.e., the thunderstorm precipitation area and the 20-dBZ area over the SCS are twice the size of those in South China, and the average 20-dBZ echo top height is 1.25 km higher over the SCS. Nevertheless, thunderstorms in South China develop more intensely, with elevated heights of the intense convective core (40-dBZ echo) compared with those thunderstorms over the SCS. The mean values of the 37-GHz minimum polarization-corrected temperature (PCT) are comparable between the two regions, but the mean value of the 85-GHz PCT is lower over the SCS, suggesting a higher concentration of small ice particles in SCS thunderstorms. Finally, a conceptual diagram that highlights the differences in thunderstorm structure and lightning flash properties between South China and the SCS is proposed. Compared with previous studies, this study has elucidated the distinct characteristics of oceanic lightning over the SCS, and highlighted the gradual transition of thunderstorm scale and lightning properties from land, to the SCS, and finally to the deep ocean area of the Northwest Pacific Ocean.

References

【1】
【1】
 
 
Journal of Meteorological Research
Pages 415-430

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
DING J, ZHANG W, ZHENG D, et al. Thunderstorm Structure and Lightning Properties in South China and over the South China Sea: A Comparative Study. Journal of Meteorological Research, 2025, 39(2): 415-430. https://doi.org/10.1007/s13351-025-4091-8

787

Views

2

Crossref

2

Web of Science

4

Scopus

1

CSCD

Received: 12 July 2024
Published: 23 February 2025
© The Chinese Meteorological Society and Springer-Verlag Berlin Heidelberg 2024