AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Regular | Open Access

Optimized Potassium Ion Detection Using Angular Interrogation SPR Enhanced by Multiwalled Carbon Nanotube-Nanocrystalline Cellulose

Wan Mohd Ebtisyam Mustaqim Mohd DANIYAL1( ), Ahmad Ashrif A. BAKAR2( ), Mohd Hafiz Abu BAKAR3, Nur Hidayah AZEMAN2, Yap Wing FEN4, Mohammed Thamer ALRESHEEDI5, Mohd Adzir MAHDI6( )
School of Distance Education, Universiti Sains Malaysia, Pulau Pinang 11800, Malaysia
Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Selangor 43600, Malaysia
Institute of Power Engineering, Universiti Tenaga Nasional, Selangor 43000, Malaysia
Faculty of Science, Universiti Putra Malaysia, Selangor 43400, Malaysia
College of Engineering, King Saud University, Riyadh 11421, Kingdom of Saudi Arabia
Faculty of Engineering, Universiti Putra Malaysia, Selangor 43400, Malaysia
Show Author Information

Abstract

This study presented the enhancement of a plasmonic optical sensor utilizing the surface plasmon resonance (SPR) to detect potassium ions (K+). The sensor performance was improved by integrating a nanocomposite carbon-based material, i.e., multiwalled carbon nanotubes-nanocrystalline cellulose (MWCNT-NCC), as the sensing layer. The SPR curve analysis was carried out by the evaluation of critical parameters, including the detection range, binding affinity, sensitivity, full width at half maximum (FWHM), data accuracy (DA), and signal-to-noise ratio (SNR). The results showed that the sensor detection range was between 0.08 ppm and 0.6 ppm before reaching saturation. The sensor also had a good sensitivity value of 0.5956 °·ppm−1. The Langmuir and Sips isotherm models were used for the binding affinity, and the calculated binding affinity constants were 1.586 6×105 M−1 and 1.644 1×105 M−1, respectively, much higher than the previously reported binding affinity constant for metal ion detection. Based on the Fourier transform infrared spectroscopy (FTIR) and X-ray photoelectron spectroscopy (XPS) analysis, it was demonstrated that the MWCNT-NCC thin film contained COOH functional groups that might bind with K+ through the electrostatic interaction, leading to improved sensing capabilities of the sensor.

References

【1】
【1】
 
 
Photonic Sensors
Article number: 250428

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
DANIYAL WMEMM, BAKAR AAA, BAKAR MHA, et al. Optimized Potassium Ion Detection Using Angular Interrogation SPR Enhanced by Multiwalled Carbon Nanotube-Nanocrystalline Cellulose. Photonic Sensors, 2025, 15(4): 250428. https://doi.org/10.1007/s13320-025-0758-0

773

Views

2

Crossref

1

Web of Science

1

Scopus

0

CSCD

Received: 15 February 2024
Revised: 27 June 2024
Published: 10 October 2025
© The Author(s) 2025.

This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.