AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Regular | Open Access

Simultaneous Measurement of Liquid Level and Refractive Index Employing a Side-Polished Spiral Polymer Optical Fiber Based SPR Sensor

Chuanxin TENG1( )Rongping YANG1Rui MIN2Jiangrong LU3Shijie DENG1Minmin XUE1Ming CHEN1Libo YUAN1Xuehao HU4
Guangxi Key Laboratory of Optoelectronic Information Processing, Guilin University of Electronic Technology, Guilin 541004, China
Center for Cognition and Neuroergonomics, State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Zhuhai 519087, China
School of Materials Science and Engineering, Guilin University of Electronic Technology, Guilin 541004, China
Department of Electromagnetism and Telecommunication, University of Mons, Mons 7000, Belgium
Show Author Information

Abstract

The work describes a surface plasmon resonance (SPR) sensor that measures the liquid level and refractive index (RI) simultaneously. The sensor is fabricated by a polymer optical fiber (POF) with a side-polished spiral structure. The POF is wound around a plastic rod with the same pitch and polished into a series of separated side-polished areas to form the sensor probe. Afterwards, the polished surfaces are coated with a gold layer to construct the SPR sensor. The proposed sensor can provide multi-point liquid-level measurement besides RI sensing. The influences of structural parameters such as the bending radius, polishing depth, and pitch on the sensing performance are experimentally studied. The experimental results indicate that the RI could be determined by employing the SPR wavelength shift, and the RI sensitivity of 1862 nm/RIU within the 1.34–1.40 range is obtained. Moreover, the SPR peak’s depth variation can be utilized to monitor the liquid level, and the sensor can provide adjustable resolution and a measurement range for liquid level sensing. With its simple fabrication, low cost, and flexible sensing ability, this sensor probe is suitable for the usage in biochemical applications.

References

【1】
【1】
 
 
Photonic Sensors
Article number: 250318

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
TENG C, YANG R, MIN R, et al. Simultaneous Measurement of Liquid Level and Refractive Index Employing a Side-Polished Spiral Polymer Optical Fiber Based SPR Sensor. Photonic Sensors, 2025, 15(3): 250318. https://doi.org/10.1007/s13320-025-0723-y

543

Views

5

Crossref

4

Web of Science

6

Scopus

0

CSCD

Received: 09 November 2023
Revised: 01 January 2024
Published: 13 June 2025
© The Author(s) 2025.

This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.