AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Regular | Open Access

Ultrafast and Reproducible Fiber-Optic Hydrogen Sensor via a Tilted Fiber Grating With Pd/WO3 Nanocoating

Zhiyong YANG1,†, Xiangyu YAN1,†, Bo PENG2,†, Zhencheng LI1, Xudong XIA1, Changhai LU1, Daotong YOU1, Kaiwei LI1,3( ), Tuan GUO1( )
Institute of Photonics Technology, College of Physics and Optoelectronic Engineering, Jinan University, Guangzhou 510632, China
Institute for Environmental and Climate Research, Jinan University, Guangzhou 511443, China
Key Laboratory of Bionic Engineering of Ministry of Education, Jilin University, Changchun 130022, China

†These authors contributed equally to this work and should be considered co-first authors

Show Author Information

Abstract

Hydrogen, a high-density and clean energy, has been widely used in various critical applications. However, the safety risk caused by hydrogen leakage during storage and transportation is still a non-negligible issue. Therefore, it is necessary to offer hydrogen sensors with fast response and high repeatability, and it will be perfect for achieving in situ monitoring over the lifecycle of hydrogen production and utilization. Here, we propose a compact optical fiber sensor with a short section of the tilted Bragg fiber grating (TFBG) inscribed in the fiber core and a palladium and tungsten trioxide (Pd/WO3) combined film of 40 nm thickness over the fiber surface. The TFBG excites tens of narrow cladding resonances, part of which possess refractive indexes matching that of the Pd/WO3 coating and providing the high sensitivity to the surrounding hydrogen concentration change. The sensor offers improved sensing characteristics, including the fast response time (less than 10 s), high repeatability (over tens of measurement), and excellent linear response (higher than 99.6%) over the 0% to 3% concentration range.

References

【1】
【1】
 
 
Photonic Sensors
Article number: 250229

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
YANG Z, YAN X, PENG B, et al. Ultrafast and Reproducible Fiber-Optic Hydrogen Sensor via a Tilted Fiber Grating With Pd/WO3 Nanocoating. Photonic Sensors, 2025, 15(2): 250229. https://doi.org/10.1007/s13320-024-0748-7
Part of a topical collection:

1115

Views

20

Crossref

18

Web of Science

19

Scopus

0

CSCD

Received: 14 October 2023
Revised: 17 April 2024
Published: 01 June 2025
© The Author(s) 2024.

This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.