Regarding the dependence of the treatment of removing polymethyl methacrylate (PMMA) from graphene upon the prestress in the film, two typical PMMA removal methods including acetone-vaporing and high-temperature annealing were investigated based on the opto-mechanical behaviors of the developed optical fiber Fabry-Perot (F-P) resonant sensor with a 125-μm diameter and ~10-layer-thickness graphene diaphragm. The measured resonant responses showed that the F-P sensor via annealing process exhibited the resonant frequency of 481kHz and quality factor of 1034 at ~2 Pa and room temperature, which are respectively 2.5 times and 33 times larger than the acetone-treated sensor. Moreover, the former achieved a high sensitivity of 110.4 kHz/kPa in the tested range of 2Pa–2.5kPa, apparently superior to the sensitivity of 16.2kHz/kPa obtained in the latter. However, the time drift of resonant frequency also mostly tended to occur in the annealed sensor, thereby shedding light on the opto-mechanical characteristics of graphene-based F-P resonant sensors, along with an optimized optical excitation and detection scheme.
This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.